ZT-2017
Zigbee Wireless 8-channel Analog Input (Current) Zigbee Data Acquisition Module with High Common Voltage Protection, Supports DCON and Modbus RTU Protocols and operating temperatures from -25 °C ~ +75 °C (-13F ~ 167F), communication distance up to 700 meters (2297 feet).
References & Support
Features
The ZT-2017 is a wireless 16-bit, 8-channel differential analog input ZigBee module that provides a programmable input range on all analog channels (+/-150 mV, +/-500 mV, +/-1 V, +/-5 V or +/-10 V) . Each analog channel can be configured for an individual input range and has a high 240 Vrms overvoltage protection. Users can easily to configure the module address, protocol, checksum, ZT-PID, ZT-channel and type code settings using a combination of rotary and DIP switches.
- ISM 2.4 GHz Operating Frequency
- Fully Compliant with 2.4G /ZigBee Specifi cations
- Wireless Transmission Range up to 700 m
- GUI Confi guration Software (Windows Version)
- 8 Differential Analog Input Channels (mV, V)
- Individual Channel Confi guration
- Overvoltage Protection up to 240 Vrms
- EFT and ESD Protection
- DIN-Rail Mounting
Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote Diagnosis, Testing Equipment.
Specifications
Communication Interface | |
Wireless Standards | ZigBee 2007 Pro |
Transmission Power | 11 dBm(FCC Certifi cated) ( Max 19 dBm) |
2.4 GHz Antenna | 5 dBi Omni directional |
Transmission Range (LoS) | 700 m (Typical) |
Certification | CE/FCC, FCC ID |
Max. Slaves in a ZigBee Network | 255 |
ZB-100R/ZB-100T Support | - |
Protocols | Supports DCON and Modbus RTU Protocols |
Hot Swap | Rotary and DIP switch |
LED Indicators | |
Power | 1 LED, red |
ZigBee Communication | 1 LED, green |
Power | |
Power Consumption | 1.4 W Max. |
Mechanical | |
Flammability | Fire Retardant Materials (UL94-V0 Level) |
Dimensions (W x L x H) | 33 mm x 87 mm x 107 mm |
Installation | DIN-Rail |
Environment | |
Operating Temperature | -25 °C ~ +75 °C |
Storage Temperature | -30 °C ~ +80 °C |
Relative Humidity | 10 ~ 90% RH, Non-condensing |
Analog Input | ||
Input Channels | 8 Differential | |
Input Types | +/-10 V, +/-5 V, +/-1V, +/-500 mV, +/-150 mV or -20 mA ~ +20 mA (Requires Optional External 125 Ω Resistor) |
|
Resolution | Normal Mode | 16-bit |
Fast Mode | 12-bit | |
Sampling Rate | Normal Mode | 16-bit, 10 Samples/Sec. (Total) |
Fast Mode | 12 bit, 60 Samples/Sec. (Total) | |
Accuracy | Normal Mode | +/-0.1% of FSR |
Fast Mode | +/-0.5% of FSR | |
-3dB Bandwidth | Normal Mode | 15.7 Hz |
Fast Mode | 78.7 Hz | |
Zero Drift | +/-20 μV/°C | |
Span Drift | +/-25 ppm/°C | |
Common Mode Rejection | 86 dB | |
Normal Mode Rejection | 100 dB | |
Input Impedance | >2 MΩ | |
Overvoltage Protection | 240 Vrms | |
Individual Channel Configuration | Yes | |
Intra-module Isolation, Field-to-Logic | 3000 VDC | |
ESD Protection | +/-4 kV contact for each channel |