I-7565-CPM
USB to CANopen Master Converter. Supports operating temperatures between -25 to 75°C.
References & Support
Features
The I-7565-CPM. It's a standard CANopen protocol and has a built-in cpu of 80186 80MHz to run the I-7565-CPM firmware independently. I-7565-CPM provides a set of APIs that will sllow the user to easily control and program the device. It will also solve the complexity of protocols for the user. It can communicate between a computer and the I-7565-CPM's USB interface to remotely control the device quickly and easily, due to the I-7565-CPM's USB interface. It can create a CANopen system effectively.
Applications
Features
- Follows CiA DS-301 V4.02 and DSP-401 v2.1
- Support maximum nodes up to 10
- Support 8 kinds baud: 10Kbps, 20Kbps, 50Kbps, 125Kbps, 250Kbps, 500Kbps, 800Kbps, and 1Mbps
- Support Node Guarding protocol
- Support NMT, PDO, SDO, SYNC and EMCY protocol
- Fully compliant with USB 1.1/2.0 (Full Speed)
- Supports Auto-Seach slave device functions.
- Supports on-line adding and removing devices
- Free software development tools for windows
- Four indication LEDs (Pwr, Tx/Rx, Act and Err LEDs)
- Provides demos and utilites
- Supports all transmission types
- Provide VC++ function libraries to process CANopen message
Software Utility Features
With the free GUI tool, I-7565-CPM utillity, users can manage and integrate a CANopen slave device easily, so when you are planning or developing CANopen network applications, I-7565-CPM utility could help you to scan devices within the network and check the connection status of each device on the remote site.
- Support Auto_Scan slave nodes
- Refresh PDO data automatically
- Provide interface to assecss PDO and SDO objects
- Add and remove PDO Dynamically
- Change NMT mode for one slave or all slaves on the same net work
- Configure EMCY COBID, SYNC COBID, Guarding parameters and transmission type of PDO
- Supports pollling methods of PDOs and SDOs
- Online remove node
Specifications
Hardware |
|
CPU |
80186, 80MHz. |
SRAM/Flash/EEPROM |
512KB / 512KB /16KB |
ESD Protection |
2 kV class A and 3 kV class B |
CAN Interface |
|
Controller |
Phillips SJA1000T CAN Controller |
Transceiver |
Phillips 82C250 CAN Transceiver |
Interface |
ISO/IS 11898-2, 9-pin male D-Sub(GAN_GND, CAN_L, CAN_SHLD, CAN_H, CAN_V+, N/A for others) |
Transfer Rate |
Support 10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M bps |
Specific |
Follow CiA DS-301 V4.02 and support CiA DSP-401 V2.1 |
Slave number |
support maximum nodes up to 10 |
USB Interface |
|
Connector |
USB Type B |
Transmission speed |
921.6 kbps |
LED |
|
Round LED |
PWR LED, ACT LED, ERR LED, Tx/Rx LED. |
Software |
|
Driver |
Windows 98/ME/NT/2K/XP. |
Library |
VC++6.0 |
Power |
|
Power supply |
By USB interface. |
Mechanism |
|
Dimensions |
72mm x 101mm x 33mm (W x L x H) |