PM-3133i-100P
Modbus RTU, Isolated 3-phase power meter; includes 60A CT (Inside diameter 10 mm; wire lead 4 m) x 3 (RoHS)
Features
ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3133i series that gives you access to real-time electric usage for three-phase power measurement. With its high accuracy (<0.5%, PF=1 ), the PM-3133i series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 400 A). It operates over a wide input voltages range 10 ~ 600 VAC which allows worldwide compatibility. Built-in AC isolator protection, this means total isolation between the AC measurement side and the control side.
- True RMS Power Measurements
- Energy Analysis for 3P4W, 3P3W, 1P3W, 1P2W
- Current Measurements Up to 400 A with Different CT Ratio
- Isolated Voltage Measurements Up to 600 V
- Clip-on CT for Easy Installation
- W Accuracy Better than 0.5% (PF=1)
- Total Harmonic Distortion (THD)
- Bi-directional Energy
- Supports Modbus RTU Protocol
- Multiple Data Format
Specifications
Models | PM-3133i | PM-3133i-MTCP | PM-3133i-CPS | |
AC Power Measurement | ||||
Wiring | 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT | |||
Input Voltage | 10 ~ 600 V; built-in isolation transformer | |||
Input Current | CTØ10 mm (0.05 A~60 A); CTØ16 mm (0.1 A~100 A); CTØ24 mm (0.15 A~200 A); CTØ36 mm (0.3 A~300 A); CTØ36 mm (0.3 A~400 A). |
|||
Input Frequency | 50 Hz (Range 45 ~ 55 Hz)/60 Hz (Range 55 ~ 65 Hz) | |||
W Accuracy | Better than 0.5% (PF=1) | |||
Power Parameter Measurement | True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency (45 ~ 65 Hz) | |||
Data Update Rate | 1 Second | |||
Communication | ||||
RS-485 | Protocol | Modbus-RTU | - | - |
Baud Rate | 9600,19200 (default), 38400, 115200; DIP Switch Selectable | - | - | |
Data Format | N,8,1 (default); N,8,2; E,8,1; E,8,2; O,8,1; O,8,2 | - | - | |
Isolation | 3000 VDC | - | - | |
Ethernet (PoE) | Protocol | - | Modbus TCP | - |
CAN bus | Protocol | - | - | CANopen |
Baud Rate | - | - | 125 k (default), 250 k, 500 k,
1 M; DIP Switch Selectable |
|
Isolation | - | - | 3000 VDC | |
Power | ||||
Input Range | +12 ~ 48 VDC | +12 ~ 48 VDC or PoE | +12 ~ 48 VDC | |
Power Consumption | 2 W | |||
Environment | ||||
Temperature | Operating Temperature: -20 ~ +70°C / Storage Temperature: -25 ~ +80°C | |||
Ambient Relative Humidity | 10% ~ 90% RH, Non-condensing |