WISE-5801
Intelligent Data Logger PAC Controller with SMS capabilities, MiniOS7, communicable over Ethernet, RS-485, RS-232, Modbus TCP, Modbus RTU. Supports operating temperatures from -25 ~ +75°C WISE-5801 is phased out and replaced by WISE-5231M-4GE.
Features
The WISE-5801 has officially been phased out and will no longer be available. It has now been replaced by WISE-5231M-4GE.
WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.
WISE-5801 supports an I/O expansion bus to implement various I/O functions such as D/I, D/O, A/D and D/A according to the XW-Board. In addition, it also support ICP DAS I-7000 remote I/O modules and Modbus RTU slave devices. Based on the variety I/O module of I-7000 and the connection ability with Modbus RTU slave devices, WISE-5801 can provide user more flexibility in application field.
WISE-5801 supports Modbus TCP/RTU protocol to make seamless integration with SCADA software available. It include all advantages which WISE series controllers can provide. In addition, WISE-5801 provide data logger function with microSD card, it can record I/O channel value by event trigger or regular time period. The data files can be sent back by Email or FTP. All setting can be completed through browser.
In addition to merits inherited from the existing WISE series, WISE-5801 even provides more supports in I/O functions. It allows to connecting with a wide range of XW-Boards, I-7000 Remote I/O modules and Modbus RTU slave devices that enables users to freely choose the most suitable I/O modules. With the microSD card, it provides Data Logger function to real-time record the I/O data of the controller and send the data files by FTP or Email at a scheduled time to the control center for further administration management or data analysis. WISE-5801 also features SMS sending function for alarm report and SMS command receiving function.
SMS Setting
WISE-5801 offers SMS alarm message sending and SMS command receiving functions. For SMS alarm message sending function; WISE-5801 offers up to 12 SMS alarm settings. It allows to send pre-set SMS alarm to specific phone numbers. For SMS command receiving function; WISE-5801 allows to set up maximum 3 authorized phone numbers to receive SMS commands. WISE-5801 will execute the commands received from authorized phone numbers only. There are three types of SMS commands:
- Retrieve real-time channel data: you can retrieve specific channel
real-time data, one SMS command message can require up to 10
channel data values. To retrieve the channel data of WISE-5801, follow
the following coding rules to send a SMS command to WISE-5801
- Modify channel data: WISE-5801 allows to modify output channel and Internal Register data by SMS command. Each SMS command message allows to modify one output channel or Internal Register value. Specify the output channel or Internal Register by the coding rules as described above, add a “/” at the end of the string and then add the data value you would like to change to (For DO: input 0 or 1, 0 indicates OFF and 1 indicates ON. For AO: input the value in floating point format.)
- Modify SMS command variable data: WISE-5801 offers up to 12 SMS command variables. The status of the variables can be set as 0 or 1. The status of SMS command variable can be included in IF Condition as part of logic rules. You can send a SMS command message to modify the status of the variable, and then perform the execution of an Action that has been previously set.
In additional to edit the SMS command by command coding rules, WISE-5801 also provides an user-friendly interface for editing a SMS Quick command – a simple self-defined command string to replace the original complex SMS command(applies to Firmware v2.3 or later version). When WISE-5801 receives the SMS Quick Command, it will automatically translate it to the SMS original command, and execute the SMS command.
Specifications
CPU Module | |
CPU | 16-bit CPU |
SRAM | 768 KB |
Flash | 512 KB |
microSD Expansion | Yes, can support 1 or 2 GB microSD |
RTC (Real Time Clock) | RTC Provide seconds, minutes, hours, date of week/month; month and year |
Watchdog Timers | Yes (0.8 second) |
Communication Ports | |
Ethernet | RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators) |
COM 1 | RS-232 (TxD, RxD, RTS, CTS, GND), non-isolated, Speed: 115200 bps max. |
COM 2 | RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed : 115200 bps max. |
LED Indicators | |
System LED | Yes (Red) |
Ethernet Link LED | Yes (Green : Ethernet link detected, Flashing Green : Ethernet packet received) |
Hardware Expansion | |
I/O Expansion Bus | Yes |
SMS Function | |
Frequency Band | Quad-band 850/900/1800/1900 MHz |
Mode | Text and Unicode mode |
Power Requirements | |
Protection | Power Reverse Polarity Protection |
Frame Ground | Yes (for ESD Protection) |
Input Range | 12 ~ 48 VDC |
Redundant Power Input | Yes |
Power Consumption | 2.0 W |
Mechanical | |
Dimensions (W x H x D) | 91 mm x 132 mm x 52 mm |
Installation | DIN-Rail |
Environment | |
Operating Temperature | -25 ~ +75 °C |
Storage Temperature | -30 ~ +80 °C |
Ambient Relative Humidity | 10 ~ 90% RH (non-condensing) |
Software Specs
Functions | |
Rule Configuration Website | Access Web server on WISE controllers to edit and upload logic rules through web browser. |
36 IF-THEN-ELSE Logic Rules | 3 IF conditions with AND or OR operators 3 THEN actions and 3 ELSE actions |
48 Internal Registers | Hold temporary variables and read/write data via Modbus/TCP address. |
12 Timers | Delay / Timing functions. |
12 Schedules | Setup prescheduled routine tasks. |
12 Emails | Send Email messages to pre-set Email receivers. |
12 SMS | Send SMS to pre-set mobile phone numbers. |
12 CGI Commands | Send pre-set CGI commands. |
12 Recipes | Set up THEN/ELSE action groups. |
Data Logger | Set up the Data Logger configuration, include the data record format, and data file sending operation. |
Modbus TCP/RTU Protocol | Real time control and monitoring I/O channels and system status of controllers via SCADA software. |
IF Conditions | |
DI Channel | ON、OFF、ON to OFF、OFF to ON、Change |
AI Channel | =、>、<、>=、<=(value) |
Internal Register | |
DI Counter | =、>、<、>=、<=(value)、Change |
Timer | Timeout、Not Timeout |
Schedule | In Range、Out of Range |
SMS Command | 0、1 |
Rule Status | Enable、Disable |
THEN / ELSE Actions | |
DO Channel | ON、OFF、Pulse Output (apply to XW-Board only) |
AO Channel | Change the value |
Internal Register | |
DI Counter | Reset |
Timer | Start、Reset |
Schedule | Enable、Disable |
Send | |
SMS Alarm | |
CGI Commands | |
Recipe | Execute |
Data Logger | Start、Stop、One-Time Log |
Rule Status | Enable、Disable |