M-7016D
2-channel Strain Gauge Voltage Input & Current Input Data Acquisition Module communicable over Modbus RTU and RS-485 with LED display. With Analog Input, Voltage Output, Digital Input, and Digital Output. Supports operating temperatures between -25 to 75°C.
Features
The M-7016 series are the latest strain gauge input modules from ICP DAS. Around our surroundings, there are numerous examples of converting force into a measurable electrical output. In most cases, we need a strain gauge type load cell. How are we going to do to make the most use of the electrical output?
The M-7016 series are definitely your #1 choice! The M-7016 series not only process the data from load cells or strain gauges, but also do linear mapping at the same time for intuitive results; by user-defined corespondent table, the M-7016 series convert the data into weight directly!
In the new models, the M-7016 series support both Modbus RTU & DCON protocols.
- 2 Analog Input Channels
- Input Types & Ranges:
- ±15mV
- ±50mV
- ±100mV
- ± 500mV
- ±1V
- ± 2.5V
- ± 20mA
- Sampling Rate
Mode 1 Channel 2 Channels Sampling Rate
samples/sec10 2
- Linear Mapping
- Excitation Voltage Output : 0 ~ 10V
- Digital Input : 1 channel; this channel can also be used as a counter.
- Digital Output : 4 channel; support High/Low alarm output.
- 4 1/2 digits LED display : For the M-7016D only.
- Operating temperature: -25°C to 75°C
- Support both Modbus RTU and DCON protocols.
Specifications
Analog Input | |
Input Channels | 2 |
Input Type | ±15mV, ±50mV, ±100mV,± 500mV , ±1V,± 2.5V, ± 20mA |
Resolution | 16-bit |
Sampling Rate | 10 Samples/ Second (one-channel mode) |
2 Samples/ Second (two-channel mode) | |
Accuracy | ±0.05% FSR |
Band Width | 5.24Hz |
Zero Drift | ±0.5uV/°C |
Span Drift | 25ppm/°C |
Common Mode Rejection | 150dB |
Normal Mode Rejection | 100dB |
Overvoltage Protection | 10V (P-P) |
Input Impedance | 20M Ohms |
Intra-module Isolation, Field to Logic | 3000 VDC |
Excitation Voltage Output | |
Output Channels | 1 |
Output Range | 0 to +10V |
Max Output Load | 40mA |
Accuracy | ±0.05% of FSR |
Drift | ±50ppm/ °C |
Output Impedance | 12 Ohms |
Isolation | 3000 VDC |
Digital Input | |
Channels | 1 |
Logic Level 0 | + 1V max |
Logic Level 1 | + 3.5V to 30V |
Max Input Frequency | 50Hz |
Min. Pulse Width | 1 mS |
Digital Output | |
Channels | 4 |
Output Type | Sink, Open collector to 30V |
Output Load | 30mA max per channel |
Power dissipation | 300 mW |
Interface | |
Interface | RS-485 |
Format | N, 8, 1 |
Buad Rate | 1200 ~ 115200 bps |
LED Display | |
1 LED | as Power/ Communication indicator |
M-7016D | 4 1/2 digits |
Power | |
Input Voltage Range | +10 to +30Vdc |
Power Consumption | 2.4W (M-7016) / 3.0W (M-7016D) |
Protocol | |
Support Modbus and DCON Protocol | Yes |
Watchdog | Yes, Module, Communication (Programmable over DCON) |
Environment | |
Operating temperature | -25 to 75°C |
Storage temperature | -40 to 85°C |
Humidity | 5 to 95% RH, non-condensing |