Download Now

Enter your information or login to view the document.


×
8-channel Thermocouple Input Module. Supports +/-15mV,+/-50mV, +/-100mV, +/-500mV, +/-1V, +/-2.5V, +/-20mA input types. Replacement unit for I-87018.

I-87018W

8-channel Thermocouple Input Module. Supports +/-15mV,+/-50mV, +/-100mV, +/-500mV, +/-1V, +/-2.5V, +/-20mA input types. Replacement unit for I-87018.

  Price:  $459.00  

Fastest Delivery: (Details) X Delivery Details
We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

Features

I-87018W has a serial bus (RS-485) communication interface with DCON protocol. It can be used with our XPAC, WinPAC and ViewPAC controllers. I-87018W is a Thermocouple Input Module with 8 channels. It is a serial cartridge based I/O module that offers the ultimate in cost effective flexibility.

Specifications

Analog Input
Input Channels 8 Differential
Input Type

+/- 15mV, +/- 50mV, +/- 100mV 
+/- 500mV, +/- 1V, +/- 2.5V
-20mA ~ +20mA(Requires Optional External 125 Ohm Resistor) 
Thermocouple(J, K, T, E. R. S, B, N, C, L, M, LDIN43710)

Resolution 16-bit
Sampling Rate 10 Samples/ sec (Total)
Accuracy +/- 0.1% of FSR
-3dB BandWidth 15.7Hz
Zero Drift +/- 0.5μV °C
Span Drift +/- 25 μV/ °C
Common Mode Rejection 150 dB
Normal Mode Rejection 100 dB
Input Impedance 20M Ohms
Open Thermocouple Detection No
Overvoltage Protection -35V to +35V
Intra-module Isolation, Field to Logic 3000VDC
LED Display
1 LED as Power/ Communication Indicator
Power
Power Consumption Maximum : 0.8W
Environment
Operating Temperature -25 to 75 °C
Storage Temperature -30 to 75 °C
Humidity 5 to 95% RH, non-condensing
Dimensions
30mm x 102mm x 115mm(W x L x H)

Note:We recommend to choose I-87018Z for accurate thermocouple measurement.

Thermocouple Type

Type Range°C
J -210 ~ +760
K -270 ~ +1372
T -270 ~ +400
E -270 ~ +1000
R 0 ~ +1768
S 0 ~ +1768
B 0 ~ +1820
N -270 ~ 1300
C 0 ~ 2320
L -200 ~ +800
M -200 ~ +100
L2(DIN43710) -200 ~ +900