DN-843I-CT-10
3-channel 10 amp current input sensor with channel to channel isolation. Monitors current from inverters in solar panel and wind turbine. Turn the current into measurable voltage. Has operating temperature ranges of -25°C ~ +75°C (-13°F ~ +167°F).
Features
The maximum input range for the DN-843I-CT-10 device is from ±1 A to +/- 50 A and can be attenuated to ±1.6 V to ±10 V. The "I" version provides 3000 VDC intra-modules isolation and 3000 VDC channel to channel isolation to avoid the noise interference from inputs to outputs or channel to channel. It can be used with analog input modules such as I-7017 and I-87017 to measure the high current.
- AC/DC Source Input
- Linear Attenuation Ratio
- High Current Input Measurement
- Isolation Input
- Channel to Channel Isolation
- 4 kV ESD Protection
- RoHS Compliance
- Operating Temperature: -25°C ~ +75°C (-13°F ~ +167°F)
- Easily Wire Connection
Specifications
General | |
Channels | 3 |
Input Type | AC/DC Current |
Input Range | +/- 10 A |
Output Type | AC/DC Voltage |
Output Range | +/- 10 Vpp |
CT Type | Solid Core (closed) |
Accuracy | 1% of FSR |
Channel to Channel Isolation | Yes, 3000 Vrms |
Intra-module Isolation, Input to Output | 3000 VDC |
Bandwidth | 50 KHz |
Input Impedence | > 1 MΩ |
EMS Protection | |
ESD (IEC 61000-4-2) | +/- 4 kV contact for power line, input and output channels, +/- 8 kV air for random point |
Power Input | |
Input Range | +10 ~ +24 VDC |
Power Consumption) | 1.2 W |
Mechanical | |
Dimensions (W x L x H) |
148 mm x 83 mm x 39 mm |
Power Consumption | 1.2 W |
Environment | |
Operating Temperature | -25°C ~ +75°C (-13°F ~ +167°F) |
Storage Temperature | -30°C ~ +75°C (-22°F ~ +176°F) |