CL-211
Remote PM2.5/CO/Temperature/Humidity/Dew Point Data Logger Module. Communicable over Modbus RTU protocol.
Features
- PM2.5, CO, CO2, Temperature, Humidity and Dew Point Measurement
- Non-dispersive Infrared (NDIR) CO2 Sensor
- Up to 450,000 records with date and time stamps
- Support DCON and Modbus RTU Protocols
- Providing RS-485 Communication Interface
- Relay Output for Alarm Device or IAQ Device Control
Introduction
The CL-200 series of Data Logger devices can be used to record PM2.5, CO, CO2, Temperature, Humidity and Dew Point information, including date and time stamps, and are able to store up to 450,000 downloadable records. Real-time data can be accessed from the DL-300 Utility from anywhere and at any time using the free Windows software.Support is provided for popular industrial protocols such as DCON and Modbus RTU. The DL-300 Data Logger can be connected via widely used RS-485 communication interfaces, meaning that the device can be easily integrated into existing HMI or SCADA systems, and is easy to be maintained in a distributed control system.
Applications
- Transportation of Food or Pharmaceuticals
- Food and Beverage Industry (HACCP)
- Blood Stations and Pharmacies
- Building and Energy Management
- Warehouse Management
- Museums, Archives and Galleries
Specifications
I/O Specifications
Model | CL-211 | CL-212 | CL-213 |
PM2.5 Measurement | |||
Range | 0 ~ 400 μg/m3 | ||
Resolution | 1μg/m3 | ||
Response Time | <= 1 min. | ||
CO Measurement | |||
Range | 0 to 1000 ppm (Electrochemical) | - | 0 to 1000 ppm (Electrochemical) |
Resolution | 1 ppm | - | 1 ppm |
Accuracy | ±5% of measured value | - | ±5% of measured value |
Response Time | 30 seconds | - | 30 seconds |
Warm-up Time | 300 seconds | - | 300 seconds |
CO2 Measurement | |||
Range | - | 0 to 9999 ppm (NDIR) | |
Resolution | - | 1 ppm | |
Accuracy | - | ±40 ppm ±3% of measured value | |
Response Time | - | 120 seconds | |
Warm-up Time | - | 5 minutes | |
Temperature Measurement | |||
Range | -10 to +50°C | ||
Resolution | 0.1°C | ||
Accuracy | ±0.6°C | ||
Relative Humidity Measurement | |||
Range | 0 to 100% RH | ||
Resolution | 0.1% RH | ||
Accuracy | ±5% RH | ||
Dew Point | |||
Range | Calculated using temperature and relative humidity | ||
Resolution | 0.1°C | ||
System | |||
PM2.5/CO2/RH/T Alarm | Yes | ||
Real Time Clock | Yes | ||
Data Logger | Yes, up to 450,000 records | ||
Relay Output | Form Ax1, SPST 30 VDC @ 16 A or 250 VAC @ 16 A |
||
Interface | RS-485 | ||
Electrical | |||
Powered from Terminal Block | +10 to +30 VDC | ||
Power Consumption | 1.2 W (Max.) | ||
Mechanical | |||
Installation | Ceiling Mounting | ||
Protection Class | IP20 | ||
Dimensions (D x H) | Ø 150 mm x 53 mm | ||
Environment | |||
Operating Temperature | 0 to +50°C | ||
Storage Temperature | -30 to +75°C | ||
Humidity | 10 to 90% RH, Non-condensing |
System Specifications
Model | CL-211 | CL-212 | CL-213 |
System | |||
PM2.5/CO/CO2/RH/T Alarm | Yes | ||
Real Time Clock | Yes | ||
Data Logger | Yes, up to 450,000 records | ||
Relay Output | Form Ax1, SPST 30 VDC @ 16 A or 250 VAC @ 16 A |
||
Interface | RS-485 | ||
Electrical | |||
Powered from Terminal Block | +10 to +30 VDC | ||
Power Consumption | 1.0 W (Max.) | 1.2 W (Max.) | 1.5 W (Max.) |
Mechanical | |||
Installation | Ceiling Mounting/Wall Mounting | ||
Protection Class | IP20 | ||
Dimensions (D x H) | Ø 150 mm x 53 mm | ||
Environment | |||
Operating Temperature | 0 to +50°C | ||
Storage Temperature | -30 to +75°C | ||
Humidity | 10 to 90% RH, Non-condensing |