Features
The DN-800V series are voltage input attenuator. The maximum input range is from ±80 V to +/- 600 V and can be attenuated to ±10 V. The "I" version provide 3000 VDC intra-modules isolation and 3000 VDC channel to channel isolation to avoid the noise interference from inputs to outputs or channel to channel. It can be used with the analog input modules such as I-7017 and I-87017 etc. to measure the high voltage.
- AC/DC Source Input
- High Voltage Input Measurement
- Linear Attenuation Ratio
- High Input Impedance
- Channel to Channel Isolation for DN-848VI-10V,
DN-848VI-80V, DN-848VI-150V and DN-843VI-600V - Channel to Channel Isolation for DN-848VI-10V,
DN-848VI-80V and DN-848VI-150V - 4 kV ESD Protection
- 3 kV Surge Protection
- RoHS Compliance
- Operating Temperature: -25 °C ~ +75 °C
- Easily wire connection
Applications
Specifications
General
Channel
3
Input Type
AC/DC Current
Input Range
+/- 600 Vpp
Output Range
+/- 10 Vpp
Accuracy
1% of FSR
Chanel to Channel Isolation
Yes, 3000 VDC
Bandwidth
30 KHz
Input Impedance
> 1 MΩ
Intra-module Isolation, Input to Output
3000 VDC
EMS Protection
ESD (IEC 61000-4-2)
+/- 4 kV contact for power line, input and output channels, +/- 8 kV air for random point
Surge (IEC 61000-4-5)
+/- 3 kV for power liner
Power Input
Input Range
+10 ~ +24 VDC
Power Consumption
3.84 W
Mechanical
Dimensions (W x L x H)
122 mm x 174 mm x 24.5 mm
Installation
DIN-Rail Mounting
Environment
Operating Temp.
-25°C ~ +75°C
Storage Temp.
-30°C ~ +75°C
Humidity