Multifunction (4 AI, 2 AO, 4 DI, 4 DO) Expansion Board. Modbus/RTU Protocol. 120 VDC Overvoltage Protection for Voltage Input, with operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F)

XV310

Multifunction (4 AI, 2 AO, 4 DI, 4 DO) Expansion Board. Modbus/RTU Protocol. 120 VDC Overvoltage Protection for Voltage Input, with operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F)

  Price:  $239.00  

Features

XV310 Application Image
  • Multifunction (4 AI, 2 AO, 4 DI, 4 DO)
  • Individual Channel Configuration
  • Jumper Selectable Voltage or Current Input/Output
  • 120 VDC Overvoltage Protection for Voltage Input
  • Open Wire Detection for Current Output
  • 60 VDC Overvoltage Protection for Digital Input
  • Configurable Power-on Value Settings
  • Configurable Safe Value Settings
  • EMS Protection
  • Dual Watchdog
  • Wide Operating Temperature Range: -25°C to +75°C (-13°F to +167°F )

The XV310 is a multifunction expansion board that includes 4 analog input channels, 2 analog output channels, 4 digital input channels and 4 digital output channels that is used for VPD Series Touch Screen Controllers. It provides a programmable input range on all analog input channels (+/-1 V, +/-2.5 V, +/-5 V, +/-10 V, +/-20 mA, 0 ~ 20 mA or 4 ~ 20 mA). Analog output channels are 12- bit at +/-5 V, +/-10 V, 0 ~ 20 mA or 4 ~ 20 mA. All digital output channels can be set as alarm output. Each analog input channel can be configured for individual ranges and can provide high overvoltage protection of 120 VDC. Voltage and current inputs/outputs are jumper selectable.

Reference & Support

  • Data Sheet
  • Specifications

    Communication
    Interface RS-232/TTL
    Format N, 8, 1
    Baud Rate 115200 bps
    Protocol Modbus/RTU
    Dual Watchdog Yes, Module (2.3 secods), Communication (Programmable over DCON)
    Isolation
    Intra-module Isolations, Field-to-Logic 2000 VDC
    EMS Protection
    ESD (IEC 61000-4-2) ±4 kV Contact For Each Terminal
    ±8 kV Air For Random Terminal
    Power
    Reverse Polarity -
    Power from the Terminal Block 5 VDC
    Consumption 1.6 W Max
    Mechanical
    Dimensions (W x L x H) 59 mm x 82 mm x 13 mm
    Environmental
    Operating Temperature -25°C ~ +75°C (-13°F ~ 167°F)
    Storage Temperature -40°C ~ +80°C (-40°F ~ +185°F)
    Humidity 10 ~ 95% RH, non-condensing

    I/O Specifications

    Analog Input
    Channels 4
    Type ±1 V, ±2.5 V, ±5 V, ±10 V, ±20 mA, 0 ~ 20 mA,
    4 ~ 20 mA (Jumper Selectable)
    Resolution 16-but
    Sample Rate Normal Mode 10 Hz
    Fast Mode 200 Hz
    Accuracy Normal Mode ±0.1%
    Fast Mode ±0.5%
    Overvoltage Protection 120VDC
    Analog Output
    Channels 2
    Type 0 V ~ +5 V, ±5 V, 0 V ~ +10 V, ±10 V, 0 mA~ +20
    mA, +4 mA ~ +20 mA (Jumper Selectable)
    Resolution 12-bit
    Accuracy ±0.1%
    Voltage Output Capability 10 V @ 20 mA
    Current Load Resistance 500 Ω
    Digital Input
    Channel 4
    Type Dry Contact Source
    Wet Contact -
    On Voltage Level Dry Contact Close to GND
    Wet Contact -
    Off Voltage Level Dry Contact Open
    Wet Contact -
    Input Impedence -
    Counters Max. Count 16-bit (65535)
    Max. Input Frequency 50 Hz
    Min. Pulse Width 20 ms
    Over Voltage Protection 60 VDC
    Digital Output
    Channels 4
    Type Source
    Max. Load Current 650 mA/channel
    Load Voltage +10 to +40 VDC
    Overvoltage Protection 47 VDC
    Overload Protection Yes
    Short Circuit Protection Yes
    Power-on Value Yes, Programmable
    Safe Value Yes, Programmable

    Related Products