XV116
Expansion I/O Board for VPD Controllers with 5 Isolated Digital Inputs and 6 Relay Outputs with 16-bit Counters
Features
* Only for VPD-132/133
The XV116 provides 5 channels for digital input, as well as 6 Form A relay output channels. In addition, either sink- or source-type digital input can be selected via wire connections. All input channels can be used as 16-bit counters. The XV116 also provides options for configuring power-on and safe digital output values. 4 kV ESD protection and 3750 VDC intra-module isolation are also provided to enhance noise immunity capabilities in industrial environments.
- 5 Digital Input channels and 6 Relay Output channels
- Sink- and Source-type Digital Input
- All Digital Input Channels can be used as 16-bit Counters
- 4 kV ESD Protection
- 3750 VDC Intra-module Isolation
- Configurable Power-on Value Settings
- Configurable Safe Value Settings
- Wide Operating Temperature Range: -25 ~ + 75°C
Applications
- Industrial Automation
- Building Automation
- Food and Beverage Systems
- Control Systems
Specifications
Digital Input/Counter | |||
Input Channels | 5 | ||
Type | Dry Contact | - | |
Wet Contact | Sink/Source | ||
On Voltage Level | Dry Contact | - | |
Wet Contact | +3.5 ~ +50 VDC | ||
Off Voltage Level | Dry Contact | - | |
Wet Contact | +1 VDCMax. | ||
Input Impedance | 10 KΩ, 0.5 W | ||
Counters | Channels | 5 | |
Max. Count | 16-bit (65535) | ||
Max. Input Frequency | 100 Hz | ||
Min. Pulse Width | 5 ms | ||
Overvoltage Protection | 70 VDC | ||
Relay Output | |||
Channels | 2 (Channel 0,1) | 4 (Channel 2 ~ 5) | |
Type | Signal Relay | Power Relay | |
Form A Relay |
Contact Rating | 2 A @ 30 VDC 0.24 A @ 220 VDC 0.25 A @ 250 VAC |
6 A @ 35 VDC 6 A @ 240 VAC |
Min. Contact Load | 10 mA @ 20 mV | 100 mA @ ≧12 V | |
Contact Material | Silver Nickel, Gold-covered | Silver Cadmium Alloy | |
Operate Time | 3 ms (typical) | 5 ms (typical) | |
Release Time | 4 ms (typical) | 1 ms (typical) | |
Mechanical Endurance | 108 ops. | 30 X 106 ops. | |
Electrical Endurance | 2 X 105 ops. | 1 X 105 ops. | |
Power-on Value | Yes | ||
Safe Value | Yes |
Communication | |
Interface | RS-232/TTL |
Format | N, 8, 1 |
Baud Rate | 115200 bps |
Protocol | Modbus/RTU |
Dual Watchdog | Yes, Module (2.3 seconds), Communication(Programmable) |
Isolation | |
Intra-module Isolation, Field-to-Logic | 3750 VDC |
EMS Protection | |
ESD (IEC 61000-4-2) | +/-4kV Contact For Each Terminal |
+/-8kV Air For Random Terminal | |
Power | |
Reverse Polarity Protection | - |
Powered from Terminal Block | 5 VDC |
Consumption | 1.2 W Max. |
Mechanical | |
Dimensions (W x L x H) | 59 mm x 82 mm x 13 mm |
Environment | |
Operating Temperature | -25 ~ +75°C |
Storage Temperature | -40 ~ +85°C |
Humidity | 10 ~ 95% RH, Non-condensing |