Download Now

Enter your information or login to view the document.


×
1 I/O slot WinCE 6.0 Based Win-GRAF XPAC (OS: Multi-Language version) (RoHS)

XP-8138-CE6

1 I/O slot WinCE 6.0 Based Win-GRAF XPAC (OS: Multi-Language version) (RoHS)

  Price:  $3,699.00  

Fastest Delivery: (Details) X Delivery Details
We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

Features

The Win-GRAF XPAC-8000-CE6 Series, XP-8138-CE6, is the new generation WinCE 6.0 based Win-GRAF XPAC-CE6 (Programmable Automation Controller) from ICP DAS. The XP-8138-CE6 is equipped with (1 GHz) dual-core running Windows CE 6.0 operating system, a variety of input/output ports (VGA, USB, Ethernet, RS-232/485), and a 1 I/O slot that can be used to integrate high performance parallel I/O modules (high profile I-8K Series) or serial I/O modules (high profile I-87K series)

The benefits of running Windows CE 6.0 on a XPAC device include hard real-time capability, achievable deterministic control and allowing PAC can have a PC-like window displays and operating environment. The PACs are capable of running Win-GRAF (IEC 61131-3 Standard) software to develop logic control applications, and also supporting M.S. VS 2008 software (VB .NET, C#) to develop HMI and data management applications that can exchange data with Win-GRAF applications.

  • x86 CPU, 1.0 GHz, dual-core
  • Windows CE 6.0
  • Embedded Win-GRAF SoftLogic (IEC 61131-3)
  • Hard Real-Time Capability
  • VGA Port Output
  • Modbus RTU/TCP (Master, Slave)
  • Support eLogger HMI
  • Redundant Power Inputs
  • Support Dual PAC Redundant System
  • Operating Temperature: -25 ~ +75 °C

Win-GRAF Workbench Feature

Win-GRAF is a powerful, PLC-like, softlogic development software. It is installed on PC with windows 7 or 8. It supports the international PLC language standard - IEC 61131-3 - Ladder Diagram (LD), Function Block Diagram (FBD), Sequential Function Chart (SFC), Structured Text (ST), Instruction Set (IL), suitable to develop applications for the full range of Win-GRAF PACs from ICP DAS.

  • IEC 61131-3 Standard Open PLC Syntax (LD, FBD, SFC, ST, IL)
  • Using ST Syntax in the FBD or LD Program
  • Event Triggered Data Binding (Exchange Data between PACs)
  • Online Debugging/Control/Monitoring, Offline Simulation
  • On Line Change
  • Various Protocols:
    • Modbus TCP/UDP, Modbus RTU/ASCII Master
    • Modbus TCP, RTU Slave
    • DCON ...
  • Plenty of Functions, Function Blocks, I/O Boards
  • Redundancy (For XP-8x38-CE6 PAC only)

Specifications

System Software

OS

Windows CE 6.0

.Net Compact Framework

3.5

Embedded Service

FTP Server, ASP (Java Script, VB Script), SQL Compact Edition 3.5

SDK Provided

Dll for Visual Studio .NET 2005/2008

Multi-Language Support

English, German, French, Spanish, Russian, Italian, Japanese, Simplified Chinese, Traditional Chinese

Development Software

ISaGRAF Software

ISaGRAF Ver.3

IEC 61131-3 standard

Languages

LD, ST, FBD, SFC, IL & FC

Max. Code Size

2 MB

Scan Time

3 ~ 15 ms for normal program
15 ~ 50 ms (or more) for complex or large program

Non-Win-GRAF

Options: VS.NET 2008 (VB.NET, C#.NET, C)

CPU Module

CPU

x86 CPU, 1 GHz, dual-core

System Memory

2 GB DDR3

Non-volatile Memory, MRAM

512 KB (retain memory without battery support)

Flash

32 GB

EEPROM

16 KB

CF Card

8 GB (support up to 32 GB)

RTC (Real Time Clock)

Provide second, minute, hour, date, day of week, month, year

Programmable LED Indicator

2

64-bit Hardware Serial Number

Yes, for Software Copy Protection

Dual Watchdog Timers

Yes

Rotary Switch

Yes (0 ~ 9)

DIP Switch

Yes (8 bits)

Audio

Microphone-In and Earphone-Out

VGA & Communication Ports

VGA

Yes, (resolution: 1024 x 768, 800 x 600, 640 x 480)

Ethernet

RJ-45 x 2, 10/100/1000 Base-T (Auto-negotiating, Auto MDI/MDI-X, LED indicators)

USB 2.0

4

COM 1

Internal communication with the high profile I-87K series modules in slots

COM 2

RS-232 (RxD, TxD and GND); non-isolated

COM 3

RS-485

D2+, D2-; self-tuner ASIC inside

Isolation

3000 VDC

COM 4

RS-232/RS-485 (RxD, TxD, CTS, RTS and GND for RS-232, Data+ and Data- for RS-485); non-isolated

COM 5

RS-232 (RxD, TxD, CTS, RTS, DSR, DTR, CD, RI and GND); non-isolated

I/O Expansion Slots

Slot Number

1
Note: For High Profile I-8K and I-87K Modules Only

Mechanical

Dimensions (W x L x H), unit: mm

169 x 132 x 125 mm

Installation

DIN-Rail or Wall Mounting

Environmental

Operating Temperature

-25 ~ +75°C

Storage Temperature

-30 ~ +80°C

Ambient Relative Humidity

10 ~ 90% RH,non-condensing

Power

Input Range

+10 ~ +30 VDC

Isolation

1 kV

Redundant Power Inputs

Yes, with one power relay (1 A @ 24 VDC) for alarm

Capacity

3.7 A, 5 V supply to CPU and backplane, 1.3 A, 5 V supply to I/O expansion slots, 25 W in total

Consumption

16.6 W (0.69 A @ 24 VDC)


Win-DRAF Specifications

Protocols (Note that certain protocols require optional devices)

NET ID

1 ~ 255, for Modbus TCP/RTU Slave, user-assigned.

Modbus TCP Master

A max. of 200 IP links to access/control the devices supporting Standard Modbus TCP Slave protocol.

Modbus RTU/ASCII Master

A max. of 32 ports: COM2 ~ 33 style="color: red;">(*) to connect other Modbus Slave devices(Like M-7000). Recommend connecting no more than 32 devices in each port for better scan rate.

Modbus RTU Slave

A max. of 16 ports: COM2 ~ 33 (*) for connecting SCADA/HMI/OPC Server.

Modbus TCP Slave

Two Ethernet ports (LAN1 & LAN2) support up to 64 connections. If the PAC uses 1 connection to connect each PC/HMI, it can connect up to 64 PCs/HMIs; If the PAC uses 2 connections to connect each PC/HMI, it can connect up to 32 PCs/HMIs; If one of the Ethernet port malfunctions, the other one can still be used to connect the PC/HMI.

User-defined Protocol

Custom protocols can be applied at COM2 ~ 33 (*) by using Serial communication functions or function blocks.

DCON Remote I/O

A max. of 16 RS-485 ports: COM2 ~ 33 (*). Each port can connect max. 50 nos I-7000 series modules or 50 nos I-87xxxW I/O modules in expansion units (I-87K4, I-87K8, I-87K9, RU-87P8, RU-87P4). Recommend connecting no more than 32 modules in each port for better scan rate.

Local I/O Modules

Supports only high profile I/O modules. Slot 1 ~ 7 supports I-8xxxW parallel I/O modules and I-87xxxW serial I/O modules. (Refer Optional I/O List)

App Protection

Using the unique 64-bit (8 bytes) PAC serial number to generate a protection password by your own algorithm to protect your Win-GRAF application. Then, if someone intend to copy your application in the PAC to another new PAC with the same PAC model, this application will not work properly in that new PAC.

Redundancy

2 XP-8x38-CE6 can set a redundant system, when one is damaged or crashes, the other can still take up and continue the work. The system offers 3-line communication redundancy, LAN1, LAN2 and Alive Port (COM5), as long as one of the three communication lines still connects normally, this redundant system can normally control the process. The redundant system provides a public IP address that allows SCADA/ HMI software to access it without needing to determine which one is the Active IP.

Data Binding

Exchange data between ICP DAS Win-GRAF PAC via Ethernet ports (LAN1 and LAN2). The data transmission is event triggered. It is much efficient than polling way. Beside, user can setup the Redundant Binding in two ethernet ports by Software, then if one Ethernet port fail, it can switch to use the other port.

On Line Change

For application field that not allowed to stop the Win-GRAF program and wish to run a new program modified a little from the original program.

Modbus RTU I/O

When software enables Modbus RTU Master function, the PAC can connect ICP DAS M-7000 and tM series and LC series I/O modules which support Modbus RTU protocol.

Modbus TCP I/O

When software enable Modbus TCP Master function, the PAC can connect ICP DAS I-8KE4/8-MTCP, PETL-7000, tPET/tET series I/O modules which support Modbus TCP protocol.

HART Master

Support I-87H17W modules in slot 1 to 7 to communicate with other HART devices.

Schedule Control

Supports the "Schedule-Control Utility" (free) to implement schedule control. Each PAC can control max. 10 Targets (devices) with different schedule settings in each day / holiday / special day / season / year.

Retain Variables

Built-in the fast retain memory that can retain up to 12,000 Win-GRAF variables.

File Access and Data Log

The Win-GRAF supports file operation functions to read/write files in the PAC's micro_SD or flash memory to do data log or file access.

eLogger HMI

Support to run HMI program (developed by the eLogger) together with the Win-GRAF logic-control program in the same PAC.

Optional I/O List

Digital Input (DI)

I-8040W, I-8040PW, I-8046W, I-8051W, I-8052W, I-8053W, I-8053PW, I-87040W, I-87040PW, I-87046W, I-87051W, I-87052W, I-87053W, I-87053PW, I-87053W-A2, I-87053W-A5, I-87053W-E5

Digital Input/Output (DIO)

I-8042W, I-8050W, I-8054W, I-8055W, I-87042W, I-87054W, I-87055W

Digital Output (DO)

I-8037W, I-8041W, I-8041AW, I-8056W, I-8057W, I-87037W, I-87041W, I-87057W, I-87057PW

Digital Output (DO)

I-8037W, I-8041W, I-8041AW, I-8056W, I-8057W, I-87037W, I-87041W, I-87057W, I-87057PW

Relay Output

I-8060W, I-8063W, I-8064W, I-8068W, I-8069W, I-87061W, I-87061PW, I-87063W, I-87064W, I-87065W, I-87066W, I-87068W, I-87068W-2A, I-87069W, I-87069PW

AC Input

I-8058W, I-87053W-AC1, I-87058W, I-87059W

Analog Input (AI)

I-8017DW, I-8017HW, I-8017HCW, I-87017W, I-87017RW, I-87017RCW, I-87017DW, I-87017W-A5, I-87017ZW, I-87018W, I-87018RW, I-87018PW, I-87018ZW, I-87019PW, I-87019RW, I-87019ZW

Analog Output (AO)

I-8024W, I-87024CW, I-87024UW, I-87024DW, I-87024RW, I-87024W, I-87028CW, I-87028UW, I-87028VW, I-87028VW-20V

Multifunction (DIO, AIO)

I-87026W

Temperature Input

Thermistor

I-87005W

RTD

-87013W, I-87015W, I-87015PW

T/C

I-87018W, I-87018RW, I-87018PW, I-87018ZW, I-87019PW, I-87019RW, I-87019ZW

Strain Gauge

I-87016W

Counter/Frequency Input

I-8084W, I-87082W, I-87084W

Encoder Input

I-8093W

PWM Output

I-8088W

HART

I-87H17W

GPS

GPS-721

Communication Module

I-8112iW, I-8114W, I-8114iW, I-8142iW, I-8144iW

Temperature & Humidity Input

DL-100T485, DL-100T485-W, DL-100T485P, DL-100T485P-W (DCON Protocol) DL-100TM485, DL-100TM485-W, DL-100TM485P, DL-100TM485P-W (Modbus RTU Protocol)

* Note: COM6 ~ COM33 ports are located in the expansion boards (I-8142iW, I-8144iW, I-8112iW, I-8114W, I-8114iW) if they are installed in slot 1 ~ 7 of XP-8x38-CE6.

* ICP DAS recommends using NS-205/NS-208 or RS-405/408 (Ring Switch) Industrial Ethernet Switches.

References and Support

Customer Reviews (0)

Be the first to leave a review.

Customers who bought this item also purchased the following items

Recently Viewed Items

×

Write a Review

Name


E-mail


Phone


Rating: out of 5 Stars
Review (max 1000 characters)

characters left