Features
This product is phased out and replaced by WP-8847
The WP-8837 is a WinCE 5.0 based ISaGRAF PAC (Programmable Automation Controller). The WP-8837 is equipped with a PXA270 CPU (520 MHz) running Windows CE 5.0 Operating System, various connectivity including 10/100 Base-TX Dual Ethernet Ports, 2 or 4 RS-232/485 ports, 1 VGA, 2 USB ports, and 8 slots for high performance Parallel-type I/O modules (High Profile I-8K series) and Serial-type I/O modules (Hot-Swap High Profile I-87K series), etc. Memories come with 128 MB SRAM, 512 KB dual battery backup SRAM, 128 MB FLASH and 1 GB microSD. For redundant supporting: Dual Watchdog Timers, redundant power inputs, dual battery backup SRAM, dual Ethernet Ports. WinPAC Series will upgrade your control system!
- PXA270, 520 MHz CPU
- Windows CE 5.0
- Embedded ISaGRAF Ver.3 SoftLogic (IEC 61131-3)
- Hard Real-Time Capability
- VGA Port Output
- Modbus RTU/TCP (Master, Slave)
- Support eLogger HMI
- Redundant Power Inputs
- Operating Temperature: -25 ~ +75 °C
Software Features
- Windows CE.NET 5.0
- Embedded ISaGRAF Ver.3 SoftLogic
- Support IEC 61131-3 Standard
- Support eLogger HMI
- Hard Real-Time Capability
- Fast Boot Speed
- Accepts max. 1 MB ISaGRAF code size
Hardware Features
- PXA270 CPU (32-bit & 520 MHz)
- 128 MB SDRAM & 128 MB Flash (for WP-8x37)
- 128 MB SDRAM & 96 MB Flash (for WP-8x47)
- 1/4/8 I/O Slots
- Dual 10/100M Ethernet Ports
- 2/4 Serial Ports (RS-232/485)
- VGA: A max. of 1024*768 (for WP-8x37)
Max. 800*600 (for WP-8x47) - USB: 2 (for WP-8x37)
1 (for WP-8x47) - 64-bit Hardware Serial Number for Software Protection
Specifications
System Software
OS
Windows CE 5.0
.Net Compact Framework
3.5
Embedded Service
FTP Server, Web Server
Multilanguage Support
FTP Server, Web Server
Development Software
ISaGRAF Software
ISaGRAF Ver.3
IEC 61131-3 standard
Languages
LD, ST, FBD, SFC, IL & FC Support eLogger HMI : XP-8xx7-CE6, WP-8xx7/5xx7 and VP-2xW7/4xx7 PAC
Max. Code Size
1 MB
Scan Time
3 ~ 15 ms for normal
15 ~ 50 ms for complex or large program
Non-ISaGRAF
Options: MS eVC++ 4.0 or VS.NET 2005/2008 (VB.NET, C#.NET)
Web Service
Web HMI
PC running Internet Explorer can monitor/control PAC via Internet/modem
Security
Support three levels username and password protection. (high/middle/low)
CPU Module
CPU
PXA270, 520 MHz
SDRAM
128 MB
Dual Battery Backup SRAM
512 KB; data valid up to 5 years (for retain variables)
Flash
128 MB
EEPROM
16 KB
Memory Expansion
microSD socket with one microSD card (support up to 32 GB)
RTC (Real Time Clock)
Provide second, minute, hour, date, day of week, month, year
64-bit Hardware Serial Number
Yes, for Software Copy Protection
Dual Watchdog Timers
Yes
Programmable LED Indicator
1
Rotary Switch
Yes (0 ~ 9)
DIP Switch
Yes (8 bits)
VGA & Communication Ports
VGA
Yes
640 x 480, 800 x 600, 1024 x 768
Ethernet
RJ-45 x 2, 10/100 Base-TX (Auto-negotiating, LED indicators)
USB 1.1 (Host)
2
COM0
Internal communication with the high profile I-87K series modules in slots
COM1
RS-232 (to update firmware) (RxD, TxD and GND); non-isolated
COM2
RS-485 (Data+, Data-) with internal self-tuner ASIC;
2500 VDC isolated for WP-8137 and WP-8147; 3000 VDC isolated for other models.
COM3
Yes
RS-232/RS-485 (RxD, TxD, CTS, RTS and GND for RS-232; Data+ and Data- for RS-485);
non-isolated
COM4
Yes
RS-232 (RxD, TxD, CTS, RTS, DSR, DTR, CD, RI and GND); non-isolated
I/O Expansion Slots
Slot Number
8
Note: For High Profile I-8K and I-87K Modules Only
Mechanicals
Dimensions (W x L x H)
95 mm x 132 mm x 111 mm: WP-8137, WP-8147
231 mm x 132 mm x 111 mm: WP-8437, WP-8447
355 mm x 132 mm x 111 mm: WP-8837, WP-8847
Installation
DIN-Rail or Wall Mounting
Environmental
Operating Temperature
-25 ~ +75 °C
Storage Temperature
-30 ~ +80 °C
Ambient Relative Humidity
10 ~ 90 % RH (non-condensing )
Power
Input Range
+10 ~ +30 VDC
Isolation
1 kV
Redundant Power Inputs
Yes, with one power relay (1 A @ 24 VDC) for alarm
Capacity
25 W
Power Consumption
9.6 W
Protocols (Note that certain protocols require optional devices)
NET ID
1 ~ 255, User-assigned by software
Modbus TCP/IP Master
Link to a max. of 100 devices that support the Standard Modbus TCP/IP Slave protocol
Modbus RTU/ASCII Master
A max. of 10 ports: COM1 ~ 14 (*). (To connect to other Modbus Slave devices) Support Multi-ports.
Modbus RTU Slave
A max. of 5 ports: COM1, one of COM2/3, COM4 ~ 8 (*). (For connecting ISaGRAF, PC/HMI/OPC Server and HMI panels.)
Modbus TCP/IP Slave
Two Ethernet ports (LAN1 & LAN2) support up to 32 connections. If the PAC uses 1 connection to connect each PC/HMI, it can connect to up to 16 PCs/HMIs; If the PAC uses 2 connections to connect each PC/HMI, it can connect to up to 32 PCs/HMIs; If one of the Ethernet port malfunctions, the other one can still be used to connect to the PC/HMI.
Web HMI Protocol
Ethernet Ports for connecting a PC running Internet Explorer.
User-defined Protocol
Custom protocols can be applied at COM1~14 using Serial communication function blocks. (*)
I-7000 & I-87K RS-485 Remote I/O
One of COM2 ~ 3 supports I-7000 I/O modules, I-87K base + I-87K Serial I/O boards, or RU-87Pn + I-87K High Profile I/O boards as remote I/O. A max. of 255 I-7000/87K remote I/O modules can connect to one PAC.
M-7000 Series Modbus I/O
A max. of 10 RS-485 ports (COM1 ~ 14) (*) can support M-7000 I/O.
Each port can connect up to 32 M-7000 Modules.
Modbus TCP/IP I/O
LAN2 supports ICP DAS Ethernet I/O: I-8KE4-MTCP and I-8KE8-MTCP. If LAN2 malfunctions, it will automatically switch to LAN1 to continuously work. (The IP address for LAN1 and LAN2 should be set in the same IP domain).
FRnet I/O
Enable a max. of 8 pcs. I-8172W boards in slot 0~7 to be used to connect to FRnet I/O modules, such as FR-2053, FR-2057, FR-32R, FR-32P. Each I-8172W board can link to a max. of 256 DI plus 256 DO channels.
Send Email
Provide functions to send email with a single attached file via the Ethernet port.
Ebus
Used to exchange data between ICP DAS ISaGRAF Ethernet PACs via the Ethernet port. (LAN2 Port only)
SMS: Short Message Service
WP-84x7/88x7’s COM4/5 and WP-81x7’s COM1/COM5 can link to a GSM Modem to support SMS. The user can request data/control the controller via a cellular phone. The controller can also send data and alarms to the user’s cellular phone. (*) Optional GSM Modem: GTM-201-RS232 (850/900/1800/1900 GSM/GPRS External Modem)
MMICON/LCD
COM4 or COM5 supports the ICP DAS MMICON. (*)
UDP Server & UDP Client : Exchange Message & Auto-report
LAN1 or LAN2 supports the UDP Server and UDP Client protocols allowing messages to be sent/received to/from a PC/HMI or other device. For example, data can be automatically reported to the InduSoft's RXTX driver.
TCP Client : Exchange Message & Auto-report
LAN1 or LAN2 supports the TCP Client protocol allowing messages to be sent/received to/from a PC/HMI or other device that supports the TCP server protocol. Ex: automatically report data to InduSoft's RXTX driver, or to connect a location camera.
GPRS/SMS
Enable the I-8212W (2G/3G) card allowing short messages to be sent/received to/from or to access a dial up connection to link to the Internet and using a GPRS connection to send an email or communicate with remote stations using the "FTP Client" or the "TCP Client"/"UDP Server"/"UDP Client" protocols.
SQL Client
Support for the SQL Client function that allows data to be written (or read from) a Microsoft SQL Server (2000 SP3, 2005, 2008).
Hot-Swap and Redundant System
This redundant system has setup two "Active IP" address point to the active LAN1 and LAN2 ports always. One or more PC/HMI/SCADA can communicate with this redundant system via one of the two given active IP. So the PC/HMI/SCADA can access to the system easily without any notice about which WP-8xx7 is currently active.
Moreover, the new redundant system can integrate with the RU-87P4/87P8 Expansion Unit plus the
I-87K high-profile I/O cards to support the hot-swap application. If the I/O card is damaged, the maintenance person just takes one good-card with same model number to hot-swap the damaged one without stopping this redundant system.
CAN/CANopen
COM1, COM3 ~ COM14 (*) can connect to one I-7530 (converter: RS-232 to CAN) to support CAN/CANopen devices and sensors. One WP-8xx7 supports a max. of 10 RS-232 ports to connect a max. of 10 I-7530.
CANopen Master
Enable the I-8123W CANopen Master card to connect to other CANopen Slave devices.
HART Solutions
Enable I-87H17W modules in slots 0 to 7 used to communicate with other HART devices.
FTP Client
Enable the FTP Client to upload files from the PAC to a remote FTP server on a PC.
eLogger HMI
Provide support for the eLogger HMI. The user can design the HMI screen using the eLogger on the PC and then download it to the PAC to display the HMI on the PAC.
Optional I/O Functions (Refer to the ISaGRAF PAC I/O Selection Guide for I/O Module list)
PWM Output
High Speed PWM Module
I-7088, I-8088W, I-87088W: 8-ch. PWM outputs, software support 1 Hz ~ 100 KHz (non-continuous), duty: 0.1 ~ 99.9%
DO Module as PWM
8-ch. max. 250 Hz max. For Off=2 & On=2 ms .
Output square wave: Off: 2 ~ 32766 ms, On: 2 ~ 32766 ms.
Optional DO Boards: I-8037W, 8041W, 8041AW, 8042W, 8050W, 8054W, 8055W, 8056W, 8057W, 8060W, 8063W, 8064W, 8068W, 8069W. (Relay Output boards cannot generate fast square wave)
Counter, Encoder, Frequency
Parallel DI Counter
8-ch. max. For 1 controller. Counter val: 32-bit. 250 Hz max. Min. ON & OFF width must > 2 ms. Optional DI boards: I-8040W, 8040PW, 8042W, 8046W, 8048W, 8050W, 8051W, 8052W, 8053W, 8053PW, 8054W, 8055W, 8058W, 8063W.
Serial DI Counter
Counter input: 100 Hz max. Counter value: 0 ~ 65535 (16-bit)
Optional serial I-87K DI boards: I-87040W, 87046W, 87051W, 87052W, 87053W, 87053W-A5, 87054W, 87055W, 87058W, 87059W, 87063W.
Remote DI Counter
All remote I-7000 & I-87K DI modules support counters. 100 Hz max. value: 0 ~ 65535
High Speed Counter
I-87082W: 100 kHz max. 32 bit;
I-8084W : 250 kHz max. 32 bit
Encoder
I-8093W: 3-axis Encoder Module, max. 1M Hz for quadrant input mode, max. 4M Hz for pulse/direction and cw/ccw input mode.
I-8084W: 250 kHz max., 4-ch encoder, can be pulse/direction, or Up/Down or A/B phase (Quad. mode); Not support Encoder Z-index.
Frequency
I-87082W: 2-ch, 1 Hz ~ 100 kHz;
I-87088W: 8-ch, 0.1 Hz ~ 500 kHz;
I-8084W : 8-ch, 1 Hz ~ 250 kHz;
Motion
Motion Control
Can be integrated with one I-8091W (2-axis) or two I-8091W (4-axis)
* Note: The COM5 ~ COM14 ports are located in the expansion boards if they are installed in slots 0 ~ 7 of WP-8xx7. WP-8137/8147 has no COM3 & COM4.