ISaGRAF IEC61131 based Windows embedded Programmable Automation Controller (PAC) with Windows CE .NET 5.0 OS, Ethernet, USB, RS-485 and RS-232 ports and din rail mount. Supports I/O expansion bus. Supports operating temperatures between -25C to 75C (-13F ~ 167F).  Comes with free SoftGRAF HMI development software and eLogger data logging software.

WP-5147

ISaGRAF IEC61131 based Windows embedded Programmable Automation Controller (PAC) with Windows CE .NET 5.0 OS, Ethernet, USB, RS-485 and RS-232 ports and din rail mount. Supports I/O expansion bus. Supports operating temperatures between -25C to 75C (-13F ~ 167F). Comes with free SoftGRAF HMI development software and eLogger data logging software.

    Item Not Available  


Features

This module has been phased out and replaced by the WP-5238-CE7

WP-5147 and WP-5147-OD Series are equipped a PXA270 CPU (520 MHz) running a Windows CE.NET 5.0 operating system, various connectivity (VGA, USB, Ethernet, RS-232/485) and I/O expansion bus for one XW-Board. The benefits of running Windows CE 5.0 on WinPAC features hard real-time capability, small core size, fast boot speed, interrupt handling at a deeper level and achievable deterministic control. WinPAC is also capable of running ISaGRAF and PC-based control software such as Visual Basic .NET, Visual C#,…. etc. It has all of the best features of both traditional PLCs and Windows capable PCs.

Running HMI and Control Logic in the Same PAC
soft graf New!!
meter
Trend and Gauge meter
alarm msg
Alarm Lists

Software Features

  • Windows CE.NET 5.0 Core
  • ISaGRAF Ver.3 SoftLogic Inside
  • Support IEC 61131-3 Standard
  • Support Soft-GRAF HMI
  • Hard Real-Time Capability
  • Accepts max. 1 MB ISaGRAF code size

Hardware Features

  • PXA270 CPU (32-bit & 520 MHz)
  • VGA: Max. 800*600
  • I/O Expansion Bus
  • Audio with Microphone-In and Earphone-Out
  • Dual 10/100M Ethernet Ports
  • 64-bit Hardware Serial Number for Software Protection
  • 3 Serial Ports (RS-232/485)
  • Operating Temperature: -25 ~ +75 °C

Applications

temperature

Measure Humidity and Temperature Values via DL-100TM485

winCE

2G/3G Wireless Application

client

Database Application

Soft-GRAF: Create A Colorful HMI Modbus RTU/TCP Slave Ports
Modbus RTU/ASCII Master Ports
eLogger HMI Application Modbus TCP/IP Master
Redundant Communication System SMS: Short Message Service
Redundant System with Ethernet I/O Multiple Web HMI - Monitor & Control Everywhere!
Redundant System with RS-485 I/O Data Recorder and Data Logger
Remote I/O Modules and Expansion module/board Data Exchange: Ebus
ZigBee Wireless Solution VIP Communication Security
Integrate with CAN/CANopen Devices and Sensors As a Modbus Gateway for the Remote I/O Modules
Send Email with One Attached File
"Applications Supporting List" & all applications

Specifications

Models WP-5147 WP-5147-OD
System Software  
OS Windows CE 5.0 Core
.Net Compact Framework 3.5
Embedded Service FTP Server, Web Server
Multilanguage Support English, German, French, Spanish, Russian, Italian, Korean, Simplified Chinese, Traditional Chinese
Development Software  
ISaGRAF Software ISaGRAF Ver.3 IEC 61131-3 standard
Languages LD, ST, FBD, SFC, IL & FC
Support Soft-GRAF HMI : XP-8xx7-CE6, XP-8xx7-Atom-CE6, WP-8xx7/5xx7 and VP-2xW7/4xx7 PAC
Max. Code Size 1 MB
Scan Time 3 ~ 15 ms for normal program
15 ~ 50 ms for complex or large program
Non-ISaGRAF Options: MS eVC++ 4.0 or VS.NET 2005/2008 (VB.NET, C#.NET)
CPU Module  
CPU PXA270, 520 MHz
SDRAM 128 MB
Flash 64 MB
EEPROM 16 KB
Expansion Flash Memory microSD socket with one microSD card (support up to 32 GB)
Battery Backup SRAM Require one XW608, 512 KB (for retain variables)
RTC (Real Time Clock) Provide second, minute, hour, date, day of week, month, year
64-bit Hardware Serial Number Yes, for Software Copy Protection
Dual Watchdog Timers Yes
LED Indicator 1 LED for Power and Running
2 LEDs for user programmable
Rotary Switch Yes (0 ~ 9)
VGA & Communication Ports
VGA Yes ; 640 x 480, 800 x 600
Ethernet RJ-45 x 2, 10/100 Base-TX
(Auto-negotiating, Auto MDI/MDI-X, LED indicators)
USB 1.1 (client) 1
USB 1.1 (host) 1
Audio - Microphone-In and Earphone-Out
COM1 RS-232 (RxD, TxD and GND); Non-isolated
COM2 RS-485 (Data+, Data -); 2500 VDC isolated
COM3 RS-232 (RxD, TxD and GND); Non-isolated
I/O Expansion  
I/O Expansion Bus Yes; to mount one optional XW-Board . 
No supporting XW5xx board (i.e. XW506, XW507, XW508, XW509, XW511i, XW514)
Mechanical  
Dimensions (W x L x H) 91 mm x 132 mm x 52 mm
Installation DIN-Rail Mounting
Environmental  
Operating Temperature -25 ~ +75 °C
Storage Temperature -30 ~ +80 °C
Ambient Relative Humidity 10 ~ 90 % RH (non-condensing )
Power  
Input Range +10 ~ +30 VDC
Isolation 1 kV
Consumption 4.8 W 6 W
Protocols (some protocols need optional devices)
NET ID 1 ~ 255, User-assigned by software
Modbus TCP/IP Master Link to max. 100 devices that support Standard Modbus TCP/IP Slave protocol.
Support one or more tGW-700 series gateway (Modbus TCP to Modbus RTU/ASCII) to expand many 
Modbus RTU / ASCII master ports to connect many Modbus RTU / ASCII slave devices.
Modbus RTU/ASCII Master Support Multi-port. Max. 10 ports
Modbus RTU Slave Max. 5 ports
Modbus TCP/IP Slave Ethernet LAN1 & LAN2 support total up to 32 connections. When one Ethernet port is broken, the other one can still connect to PC/HMI.
Web HMI Protocol Ethernet Ports for connecting PC running Internet Explorer.
User-Defined Protocol COM1 ~ COM3 by Serial communication function blocks.
I-7000 & I-87K RS-485 
Remote I/O
COM2 supports I-7000 I/O modules, I-87K base + I-87K Serial I/O boards and RU-87Pn + I-87K High Profile I/O boards as Remote I/O. Max. 255 modules for one controller.
M-7000 Series Modbus I/O Max. 10 RS-485 ports (*) can support M-7000 I/O. Each port can connect up to 32 M-7000 Modules.
Modbus TCP/IP I/O LAN2 supports ICP DAS Ethernet I/O: I-8KE4-MTCP and I-8KE8-MTCP. If LAN2 is broken, it will switch to LAN1 automatically to continuously work. (LAN1 & LAN2's IP are requested set in the same IP domain)
Send Email Supports functions to send Email with one attached file via Ethernet port.
Ebus LAN2 to exchange data between ISaGRAF Ethernet PAC via Ethernet port.
UDP Server & UDP Client :
Exchange Message & Auto-Report
LAN1 or LAN2 support UDP Server and UDP Client protocol to send/receive message to/from PC/HMI or other devices.
TCP Client :
Exchange Message & Auto-Report
LAN1 or LAN2 supports TCP Client protocol to send/receive message to/from PC/HMI or other devices which support TCP server protocol. Ex: automatically report data to InduSoft's RXTX driver, or to connect a location camera.
Soft-GRAF HMI Support the Soft-GRAF HMI. User can use the Soft-GRAF Studio on the PC to design the HMI screen and then download it to the PAC to display the HMI on the PAC.
SQL Client Support SQL Client function to write data to (or read data from) Microsoft SQL Server (2000 SP3, 2005, 2008).
CAN/CANopen COM1, COM3 can connect one I-7530 (converter: RS-232 to CAN) to support CAN/CANopen devices and sensors. One WP-5xx7 supports max.10 RS-232 ports to connect max. 10 I-7530.
FTP Client Support FTP client to upload files in the PAC to a remote FTP server on PC.
Soft-GRAF’s g_Alarm & g_Logger1 HMI objects support FTP client, too.
*Note: COM5 ~ COM12 are resided at the optional expansion XW-Board series if it is plugged inside the WP-5xx7.
* Recommend to use NS-205/NS-208 or RS405/RS408 Industrial Ethernet Switch.

Customer Reviews (0)

Be the first to leave a review.

Recently Viewed Items

×

Write a Review

Name


E-mail


Phone


Rating: out of 5 Stars
Review (max 1000 characters)

characters left