8-channel Thermistor Input (Analog Input) and 4-channel Isolated Digital Output PoE Modbus TCP Protocol Module. Built-in Web Server, with operating temperature range of -25°C ~ +75°C (-13° ~ +167°F)

WISE-7105

8-channel Thermistor Input (Analog Input) and 4-channel Isolated Digital Output PoE Modbus TCP Protocol Module. Built-in Web Server, with operating temperature range of -25°C ~ +75°C (-13° ~ +167°F)

  Price:  $599.00  

Features

Application Image WISE-7105

WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.

WISE-7105 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7105 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc.

This multi-function module WISE-7105 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 16-bit, 8-channel Thermistor inputs and 4-channel digital outputs. Each analog channel is allowed to configure an individual range.

  • Built-in Web Server for IF-THEN-ELSE rule setting
  • Built-in IF-THEN-ELSE rule enigne for logic operation
  • No more programming. Just click and get done!
  • Support IO, Counter, Timer, Email operations
  • Modbus/TCP Protocol for SCADA Software Seamless Integration
  • IEEE 802.3af-compliant Power over Ethernet (PoE)
  • 10/100 Base-TX Ethernet
  • Support Thermistor Input
  • Individual Channel Configuration
  • 4-channel Digital Outputs
  • 2-way Isolation/ESD Protection

Specifications

Analog Input
Input Channels 8 (Differential)
Input Type Precon ST-A3, Fenwell U, YSI L100, YSI L300, YSI L1000, YSI B2252, YSI B3000, YSI B5000,YSI B6000, YSI B10000, YSI H10000, YSI H3000
Resolution 16-bit
Sample Rate 10 Sample/Sec. (Total)
Accuracy +/-0.1% or bette
Zero Drift +/-20 μV/°C
Span Drift +/-25 ppm/°C
Overvoltage Protection 110 VDC/VAC
Common Mode Rejection 86 dB min.
Normal Mode Rejection 100 dB
Open Wire Detection Yes
Individual Channel Configuration Yes
Digital Output
Output Channels 4
Output Type Isolated Open Collector (Sink)
Max. Load Current 700 mA/Channel
Load Voltage 5 VDC ~ 50 VDC
Overvoltage Protection 60 VDC
Overload Protection 1.4 A
Short-circut Protection Yes
System
CPU 16-bit CPU
SRAM 512 KB
Flash Memory 512 KB
EEPROM 16 KB
Watchdog Yes, Programmable over DCON
Communication
PoE 10/100 Base-TX and automatic MDI/MDI-X
2-way Isolation
Ethernet 2500 VDC
LED Indicators
PoE PoE On
L1 System Running
L2 Ethernet Link/Act
L3 Ethernet 10/100 M Speed
EMS Protection
ESD (IEC 61000-4-2) ±4 kV Contact for each terminal and ±8 kV Air for random poin
EFT (IEC 61000-4-4) ±4 kV for Power Line
Power Requirements
Reserve Polarity Protection Yes
Powered from Terminal Block Yes, 12 ~ 48 VDC
Powered from PoE Yes, IEEE 802.3af, Class1
Consumption 3.0 W
Mechanical
Dimensions (W x H x D) 72 mm x 123 mm x 35 mm
Installation DIN-Rail or Wall mounting
Environment
Operating Temperature -25 °C ~ +75 °C (-13°F ~ +167°F)
Storage Temperature -30 °C ~ +80 °C (-22°F ~ 176°F)
Humidity 5 ~ 90% RH, non-condensing

Software Specifications

Functions
36 IF-THEN-ELSE Logic Rules 3 IF conditions with AND or OR operators
3 THEN actions
3 ELSE actions
48 Internal Registers Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers Delay / Timing functions.
12 Emails Send Email messages to pre-set Email receivers.
12 CGI Commands Send pre-set CGI commands.
12 Receipts Set up Then/ELSE action groups.
Rule Configuration Website Access Web server on WISE controllers to edit and upload logic rules through web browser.
Modbus/TCP Protocol Real time control and monitoring I/O channels and system status of controllers via SCADA software.
IF Conditions
AI Channel ON、OFF、ON to OFF、OFF to ON、Change
Internal Register =、>、<、>=、<=(value)
Rule Status Enable、Disable
P2P DI、AI、DI counter、DO counter、IR
DO Counter =、>、<、>=、<=(value)、Change
Timer Timeout、Not Timeout
THEN / ELSE Actions
DO Channel ON、OFF、Pulse Output
Internal Register Change the value
DO Counter Reset
Timer Start、Stop
Email Start、Stop
CGI Commands
Recipe Execute
P2P DO(On/Off)、AO、IR
Rule Status Enable、Disable

Related Products