Download Now

Enter your information or login to view the document.


×
ISaGRAF based ViewPAC with 10.4” Touch LCD, Windows CE.NET 5.0 Operating System and 3 I/O slots, communicable over Ethernet, RS-485 and RS-232, Modbus TCP, Modbus RTU, supports operating temperatures from -20 ~ +70°C. Ingress Protection - Front panel: IP65. VP-4137 is phased out and replaced by VP-4238-CE7.

VP-4137

ISaGRAF based ViewPAC with 10.4” Touch LCD, Windows CE.NET 5.0 Operating System and 3 I/O slots, communicable over Ethernet, RS-485 and RS-232, Modbus TCP, Modbus RTU, supports operating temperatures from -20 ~ +70°C. Ingress Protection - Front panel: IP65. VP-4137 is phased out and replaced by VP-4238-CE7.

    Item Not Available  


References & Support


Features

The VP-4137 has officially been phased out and will no longer be available. It has now been replaced by VP-4238-CE7.

VP-4137VP-4137 is part of the new generation ISaGRAF based PACs. ViewPAC integrates WinPAC, a color graphic display with keypad or touch function, into one unit. It is equipped with a PXA270 CPU (520 MHz), various connectivity (USB, Ethernet, RS-232/485), 3 I/O slots, 3.5” TFT LCD and a rubber keypad or 5.7”/10.4” TFT Touch LCD. The benefits of running Windows CE 5.0 on ViewPAC include hard real-time capability, small core size, fast boot speed, interrupt handling at a deeper level, and achievable deterministic control. ViewPAC is also capable of running ISaGRAF and PC-based control software such as Visual Basic .NET, Visual C#, …. etc.

ISaGRAF is the most powerful SoftLogic package on the market. ISaGRAF is a PLC-like software and it supports IEC 61131-3 standard PLC programming languages (LD, FBD, SFC, ST, IL, FC), and can run the application generated by the workbench on any ISaGRAF PACs. The ISaGRAF workbench Ver. 3.x features

  • IEC 61131-3 Standard Open PLC Programming Languages (LD, FBD, SFC, ST, IL, FC) + Flow Chart (FC)
  • Auto-Scan I/O
  • On-Line Debug/Control/Monitor, Off-Line Simulation
  • Simple Graphic HMI
  • Support Soft-GRAF HMI

appliction

Specifications

System Software  
OS  Windows CE 5.0  
.Net Compact Framework 
3.5 
Embedded Service  FTP server, Web server (supports VB script, JAVA script), Embedded SQL server  
SDK Provided  Dll for eVC, Dll for Visual Studio.Net 2005/2008  
Multilanguage Support  English, German, French, Spanish, Russian, Italian, Korean, Simplified Chinese, Traditional Chinese  
Development Software  
ISaGRAF Software  IEC 61131-3 standard 
Languages  LD, ST, FBD, SFC, IL & FC; Support Soft-GRAF HMI: XP-8xx7-CE6/8xx7-Atom-CE6, WP-8xx7/5xx7 and VP-2xW7/4xx7 PAC  
Max. Code Size  1 MB  
Scan Time  3 ~ 15 ms for normal program 15 ~ 50 ms (or more)for complex or large program  
Non-ISaGRAF  Options: MS eVC++ 4.0 or VS .NET 2005/2008 (VB.NET, C# .NET)  
Web Service  
Web HMI  PC running Internet Explorer can monitor/control PAC via Internet/modem  
Security  Support three-level username and password protection. (high/middle/low)  
CPU Module  
CPU  PXA270, 520 MHz  
SDRAM  128 MB  
Flash  128 MB 
Expansion Flash Memory  microSD socket with one microSD card (support up to 32 GB)  
Dual Battery Backup SRAM  512 KB; data valid up to 5 years (for retain variables)  
EEPROM  16 KB  
RTC (Real Time Clock)  Provide second, minute, hour, date, day of week, month, year  
64-bit Hardware Serial Number  Yes, for Software Copy Protection  
Dual Watchdog Timers  Yes (0.8 second)  
Rotary Switch  Yes (0 ~ 9)  
Communication Interface  
Ethernet  RJ-45 x 2 
 10/100 Base-TX (Auto-negotiating, LED indicators) 
USB 1.1 (host) 
2
USB 1.1 (client) 
1
COM 0  Internal communication with the high profile I-87K series modules in slots  
COM 1 
COM 2  RS-485 (Data+, Data-) with internal self-tuner ASIC; 2500 VDC isolated  
COM 3  RS-232 (RxD, TxD, CTS, RTS, DSR, DTR, CD, RI and GND); Non-isolated  
MMI (Man Machine Interface)  
LCD  5.7” TFT (Resolution 640 x 480) 
Touch Panel  Yes 
Rubber Keypad  6 Keys 
Audio  Earphone-Out 
LED Indicators  2 LEDs (PWR, RUN) 
I/O Expansion Slots  
Slot Number 
 Note: For High Profile I-8K and I-87K Modules Only 
Mechanical  
Dimensions (W x L x H)  293 mm x 231 mm x 129 mm 
Installation  Panel Mounting 
Ingress Protection  Front panel: IP65 
Environmental 
Operating Temperature  -20 ~ +70°C 
Storage Temperature  -30 ~ +80°C 
Ambient Relative Humidity  10 ~ 90% RH (non-condensing) 
Power 
Input Range  +10 ~ +30 VDC 
Isolation  1 kV 
Capacity  12.5 W 
Consumption  8.5 W 

 

Protocols
NET ID    1 ~ 255, user-assigned by software  
Modbus TCP/IP Master    Link to max. 100 devices that support Standard Modbus TCP/IP Slave protocol (FAQ-113)  
Modbus RTU/ASCII Master    Max. 10 ports: COM2, 3 and COM5 ~ 14. (To connect to other Modbus Slave devices). Support Multi-port. (*)  
Modbus RTU Slave    Max. 5 Ports: one of COM2/3, COM5 ~ 8. (For connecting ISaGRAF, PC/ HMI/ OPC Server & HMI panels.) (*)  
Modbus TCP/IP Slave    Yes, LAN1 and optional 2nd Ethernet Port in I-8135W support total up to 32 connections (for connecting ISaGRAF & PC / HMI). When one Ethernet port is broken, the other one can still connect to PC/HMI.  
Web HMI Protocol    Ethernet Ports for connecting PC running Internet Explorer  
User-Defined Protocol    User can write his own protocol applied at COM2, 3 and COM5 ~ COM14 by Serial communication function blocks (*).  
I-7000 & I-87K RS-485 Remote I/ O    One of COM2 or COM3 supports I-7000 I/O modules, I-87K base + I-87K Serial I/O boards and RU-87Pn + I-87K High Profile I/O boards as Remote I/O. Max. 255 modules for one controller.  
M-7000 Series Modbus I/O    Max. 10 RS-485 ports: COM2, 3, 5 ~ 14. Each port can connect up to 32 M-7000 Modules. (with optional I-7510 repeater connected can connect up to more than 32 M-7000 Modules) (*)  
Modbus TCP/IP I/O    Supports ICP DAS Ethernet I/O : I-8KE4-MTCP and I-8KE8-MTCP (FAQ-042). If LAN1 is broken, it will switch to the 2nd Ethernet port (in optional I-8135W card) automatically to continuously work. (This need LAN1 & the 2nd Ethernet's IP are set in the same IP domain)  
FRnet I/O    Support max 3 pcs. I-8172W boards in slot 0 ~ 2 to connect to FRnet I/O modules, like FR-2053, FR-2057, FR-32R, FR-32P (FAQ-082, 154). Each I-8172W board can connect up to 256 DI plus 256 DO channels.  
Send Email    Support functions to send Email with one attached file via Ethernet port.  
Ebus    To exchange data between ISaGRAF Ethernet PAC via Ethernet port. (LAN1 Port only)  
SMS: Short Message Service    COM3 or COM5 can link to a GSM Modem to support SMS. User can request data/control the controller by cellular phone. (*) The controller can also send data & alarms to user’s cellular phone. Optional GSM Modems: GTM-201-RS232 (850/900/1800/1900 GSM/GPRS External Modem)  
MMICON/LCD    COM3 or COM5 supports ICP DAS's MMICON. (*) The MMICON is featured with a 240 x 64 dot LCD & a 4 x 4 Keyboard to display picture, string, integer, fl oat, & input a char, string, integer & fl oat.  
 UDP Server & UDP Client : Exchange Message & Auto-Report    LAN1 or the 2nd Ethernet (in optional I-8135W card) support UDP Server and UDP Client protocol to send/receive message to/from PC/HMI or other devices. Ex: to automatically report data to InduSoft’s RXTX driver.  
TCP Client : Exchange Message & Auto-Report    LAN1 or the 2nd Ethernet (in optional I-8135W card) ca send/receive message to/from PC/HMI or other devices which support TCP server protocol. Ex: automatically report data to InduSoft’s RXTX driver, or to connect a location camera.  
GPRS/SMS    Support the I-8212W (2G/3G) card to receive/send a short message or to dial up to link the Internet by GPRS connection to send an email or communicate with remote stations by using "FTP Client" (FAQ-151) and "TCP Client" / "UDP Server" / "UDP Client" (FAQ-143).  
 SQL Client    Support SQL Client function to write data to (or read data from) Microsoft SQL Server (2000 SP3, 2005, 2008).  
Hot-Swap and Redundant System    Must enable the 2nd Ethernet port in the optional I-8135W card. This redundant system has setup two “Active IP” address point to the active VP-2xW7/2xW6 's LAN1 and 2nd Ethernet ports always. One or two or more PC / HMI / SCADA can communicate with this redundant system via one of the two given active IP. So the PC / HMI / SCADA can access to the system easily without any notice about which VP-2xW7/2xW6 is currently active. Moreover, the new redundant system can integrate with the RU-87P4 and RU-87P8 expansion unit plus the I-87K high-profi le I/O cards to support the hot-swap application. If the I/O card is damaged, the maintenance person just takes one good-card with same model number to hot-swap the damaged one without stopping this redundant system. (FAQ-093)  
CAN/CANopen    COM3 or COM5 ~ COM14 can connect one I-7530 (Converter: RS-232 to CAN) to support CAN/CANopen devices and sensors. One PAC supports max.10 RS-232 ports to connect max.10 I-7530. (*)  
CANopen Master    Support the I-8123W CANopen Master card to connect other CANopen slave devices. (FAQ-145)  
HART Solutions    Support I-87H17W modules in slot 0 to 2 to communicate with other HART devices.  
FTP Client    Support FTP client to upload files in the PAC to a remote FTP server on PC. (FAQ-151) Soft-GRAF’s g_Alarm & g_Logger1 HMI objects support FTP client, too. (FAQ-146)  
Soft-GRAF HMI    Support the Soft-GRAF HMI . User can use the Soft-GRAF Studio on the PC to design the HMI screen and then download it to the PAC to display the HMI on the PAC. (FAQ-146)  
 Optional I/O Functions (Refer   to ISaGRAF PAC I/O Selection Guide for I/O Module list)  
PWM Output   High Speed PWM Module    I-7088, I-8088W, I-87088W: 8-ch. PWM outputs, software support 1 Hz~100 kHz (non-continuous), duty: 0.1~99.9%  
DO Module as PWM   8-ch. max. 250 Hz max. For Off=2 & On=2 ms. Output square curve: Off: 2 ~ 32766 ms, On: 2 ~ 32766 ms. Optional DO Boards: I-8037W, 8041W, 8041AW, 8042W, 8050W, 8054W, 8055W, 8056W, 8057W, 8060W, 8063W, 8064W, 8068W, 8069W. (Relay Output boards cannot generate fast square wave)  
Counter, Encoder, Frequency    Parallel DI Counter    8-ch. max. For 1 controller. Counter val: 32-bit. 250 Hz max. Min. ON & OFF width must > 2 ms. Optional DI boards: I-8040W, 8040PW, 8042W, 8046W, 8048W, 8050W, 8051W, 8052W, 8053W, 8053PW, 8054W, 8055W, 8058W, 8063W.  
Serial DI Counter   Counter input: 100 Hz max. Counter value: 0 ~ 65535 (16-bit) Optional serial I-87K DI boards: I-87040W, 87046W, 87051W, 87052W, 87053W, 87053W-A5, 87054W, 87055W, 87058W, 87059W, 87063W.  
Remote DI Counter  All remote I-7K/I-87K DI modules support counters. 100 Hz max. Value: 0 ~ 65535  
 High Speed Counter    I-87082W: 100 kHz max., 32-bit; I-8084W: 250 kHz max., 32-bit  
Encoder I-8093W: 3-axis Encoder Module, max. 1M Hz for quadrant input mode, max. 4 MHz for pulse/direction and cw/ccw input mode. (FAQ-112) I-8084W: 250 kHz max., 4-ch encoder, pulse/direction or up/down or A/B phase (Quad. mode), Not support Encoder Z-index. (FAQ-100)  
Frequency    I-87082W: 2-ch, 1 Hz ~ 100 kHz; I-87088W: 8-ch, 0.1 Hz ~ 500 kHz; I-8084W: 8-ch, 1 Hz ~ 250 kHz;
Motion   Motion Control    one I-8091W (2-axis) or two I-8091W (4-axis) can do motion control. only one I-8091W can do X-Y dependent motion.  
Port   Second Ethernet    VP-2xW7/2xW6/4137 can add one optional I-8135W card in its slot 0 ~ 2 to expand the second Ethernet port.  

References and Support

Customer Reviews (0)

Be the first to leave a review.

Recently Viewed Items

×

Write a Review

Name


E-mail


Phone


Rating: out of 5 Stars
Review (max 1000 characters)

characters left