Remote Ethernet Modbus TCP I/O Modules

ET-7065$349.00
ADD TO CART
6 Channel Photo-Mos Relay Output and 6 Channel Isolated Digital Input Data Acquisition Module with 32-bit Counters, communicable over Ethernet and Modbus TCP Protocol. Supports operating temperatures between -25°C ~ +75°C (-13°F ~ +167°F).  More....

ET-7066$319.00
ADD TO CART
On Sale Now (Quantity limited)
ET-7066: $279.00 $195.30
8-channel Photo-Mos Relay Output Data Acquisition Module, communicable over Ethernet and Modbus TCP Protocol. Supports operating temperatures between -25°C ~ +75°C (-13°F ~ +167°F).  More....

ET-7067$319.00
ADD TO CART
8-Channel Power Relay Output Data Acquisition Module, communicable over Ethernet and Modbus TCP Protocol. Supports operating temperatures between -25°C ~ +75°C (-13°F ~ +167°F).  More....

ET-7083$459.00
ADD TO CART
Modbus TCP based Remote Ethernet I/O Data Acquisition Module with 3-axis Encoder/Counter Inputs (Digital Input). Support Modbus TCP and Modbus UDP Protocols. 32-bit Counter. Support Operating Temperatures: -25 ~ + 75°C (-13°F ~ +167°F) and has a din rail mount.   More....

PET-7016$599.00
ADD TO CART
Modbus TCP based Remote Power-over-Ethernet data acquisition module with 2-channel Strain Gauge Input, 2-channel Digital Input/Counter, 2-channel Digital Output and 1-channel Voltage Output. Strain Gauge input types are: +/-15 mV, +/-50 mV, +/-100 mV, +/-500 mV, +/-1 V, +/-2.5 V, +/-20mA, 10 ~ 20 mA, 4 ~ 20 mA. Communicable over Modbus TCP and Modbus UDP. Supports Operating Temperatures between -25°C to +75°C (-13F ~ 167F) and has a din rail mount.  More....

starstarstarstarstar (1) review
ET-7017-10$489.00
ADD TO CART
Modbus TCP based data acquisition module with 10 differential or 20 single-ended channel voltage and current Analog Input (current input) with high voltage protection and isolation, communicable over Ethernet and Modbus TCP Protocol. Supports Analog Input types: ±150mV, ±500mV, ±1V, ±5V, ±10V, ±20mA ,0~20mA, 4~20mA (jumper selectable). Supports operating temperatures between -25°C to 75°C (-13°F ~ 167°F). Has a Din rail mount.  More....

ET-7018Z$609.00
ADD TO CART
10-channel Thermocouple, Analog Input, Current Input, and Voltage Input with High Voltage Protection and 6-channel Isolated Digital Output Data Acquisition Module with short cable, communicable over Ethernet and Modbus TCP Protocol. The S2 version comes with DN-1822 Daughter Board and 1.8m Cable. Supports operating temperatures between -25°C to +75°C (-13°F ~ +167°F).  More....

ET-7019Z$689.00
ADD TO CART
Modbus TCP based Remote Ethernet I/O Data Acquisition Module with 10-channel Analog Input & Current Input (Thermocouple Input), Voltage Input with High Voltage Protection and 6-channel Isolated Digital Output, communicable over Modbus TCP and UDP, comes with DB-1820 Daughter Board. Supports operating temperatures between -25°C ~ 75°C (-13°F ~ 167°F) and has a din rail mount.  More....

10-channel Thermocouple, Analog Input, Current Input, and Voltage Input with High Voltage Protection and 6-channel Isolated Digital Output Data Acquisition Module with short cable, communicable over Ethernet and Modbus TCP Protocol. The S2 version comes with DN-1822 Daughter Board and 1.8m Cable. Supports operating temperatures between -25°C to +75°C (-13°F ~ +167°F).  More....

RS-232/422/485 Converters

I-7550E$679.00
ADD TO CART
Profibus to 10/100 Ethernet Converter. Configurable over a Web Page and allows a Profibus Master Device to access Ethernet devices over TCP/UDP. Has an operating temperature range of -25°C ~ +75°C (-13°F ~ +167°F)  More....