Data Acquisition Search Results

126 Products for "" with protocol: Modbus TCP And I/O Type:

Modbus TCP Based Dual Ethernet Port I/O Modules

ET-7251$319.00
ADD TO CART
Modbus TCP Based Ethernet I/O Module with 2 Ethernet ports for daisy-chain networking, with 16-channel Digital Input and can be configured as Wet Contact Sink or Source type. 32-bit counter. LED Indicators show the status of I/O. Communicable over Modbus TCP and Modbus UDP protocol, Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.   More....

ET-7215$419.00
ADD TO CART
Modbus TCP Based Ethernet I/O Module with 2 Ethernet ports for daisy-chain networking and 7-channel RTD Inputs. Sensor types are Pt100, Pt1000, Ni120, Cu100, Cu1000. Communicable over Modbus TCP and Modbus UDP protocol, Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.  More....

ET-7217$399.00
ADD TO CART
Modbus TCP Based Ethernet I/O Module with 2 Ethernet ports for daisy-chain networking, with 8-channel Analog Input and 4-channel Digital Output. Analog Input Types are +/-150 mV, +/-500 mV, +/-1V, +/-5V, +/-10V +/-20 mA, 0 ~ 20 mA, 4 ~ 20 mA (Jumper Selectable) current input voltage input. Communicable over Modbus TCP and Modbus UDP. Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.  More....

Modbus TCP Based Ethernet I/O Module with 2 Ethernet ports for daisy-chain networking, with 10/20-channel Analog Input. Input types are +/-150 mV, +/-500 mV, +/-1V, +/-5V, +/-10V, +/-20 mA ,0 ~ 20 mA, 4 ~ 20 mA (Jumper Selectable) Current Input and Voltage Input. Communicable over Modbus TCP and Modbus UDP. Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.   More....

ET-7202$479.00
ADD TO CART
Modbus TCP Based Ethernet I/O Module with 2 Ethernet ports for daisy-chain networking, with 3-channel Analog Input, 6-channel Digital Input/Counter, and 3-channel Power Relay Output. Supports Current Input and Voltage Input Types: +/-150 mV, +/-500 mV, +/-1 V, +/-5 V, +/-10 V +0 mA ~ +20 mA, +/-20 mA, 4 ~ 20 mA (jumper selectable). Communicable over Modbus TCP and Modbus UDP. Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.  More....

ET-7226$469.00
ADD TO CART
Modbus TCP Based Ethernet I/O Module with 2 Ethernet ports for daisy-chain networking, with 6-channel Analog Input (Current Input), 2-channel Analog Output (Current Output), 2-channel Digital Input Counter, and 2-channel Digital Output, Current Input, Voltage Input, Communicable over Modbus TCP and Modbus UDP. Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.   More....

ET-7242$319.00
ADD TO CART
Modbus TCP Based Ethernet I/O Module with 2 Ethernet ports for daisy-chain networking, with 16 Digital Outputs and can be configured as Sink type. Communicable over Modbus TCP and Modbus UDP protocol, Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.   More....

ET-7252$319.00
ADD TO CART
Modbus TCP Based Ethernet I/O Module with 2 Ethernet ports for daisy-chain networking, with 8-channel Digital Input with counter and 8-channel Digital Output, can be configured as Wet Contact Sink or Source type. Communicable over Modbus TCP and Modbus UDP protocol, Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.   More....

ET-7253$299.00
ADD TO CART
Modbus TCP Based Ethernet I/O Module with 2 Ethernet ports for daisy-chain networking, with 16-channel Digital Input, can be configured as Dry Contact Source type. Communicable over Modbus TCP and Modbus UDP protocol, Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.  More....

ET-7255$359.00
ADD TO CART
Modbus TCP Based Ethernet I/O Module with 2 Ethernet ports for daisy-chain networking, with 8-channel Digital Input with counter and 8-channel Digital Output, can be configured as as either Dry Contact Source or Wet Contact Sink or Source type. Communicable over Modbus TCP and Modbus UDP protocol, Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.  More....

Page   1 2 3 4 5 6 7 8 9 10 11 12 13 Next