Download Now

Enter your information or login to view the document.


×
Modbus TCP to HART Gateway - acts as a HART protocol Master that allows  Modbus/TCP master devices to access data from  HART slave devices. Replacement unit for I-87H17W.

HRT-711

Modbus TCP to HART Gateway - acts as a HART protocol Master that allows Modbus/TCP master devices to access data from HART slave devices. Replacement unit for I-87H17W.

  Price:  $819.00  

Fastest Delivery: (Details) X Delivery Details
We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

Features

HRT-711 applicationThe HRT-711 Modbus TCP to HART Gateway is specially designed for the master device of HART protocol. It allows the Modbus/TCP master device to access the HART slave devices. These HART devices may be a transmitter, an actuator, a current output device and so forth. In addition, we also provide the utility software for users to configure the HRT-711. By using this module, users can integrate their HART devices into Modbus network easily.

  • Support HART Short/Long frame
  • Support HART Burst mode
  • Allow two HART Masters
  • Support Modbus/TCP Format
  • Support Modbus Slave / HART Master Mode
  • Support Firmware Update via Com Port
  • Support On-line Replacement of HART Devices
  • Support Acquire Long Frame Address Automatically
  • Provide LED indicators
  • Built-in Watchdog
  • 4KV ESD Protection

The HART (Highway Addressable Remote Transducer) protocol uses the Bell 202 Frequency Shift Keying (FSK) standard to superimpose digital communication signals on the 4-20 mA loop current shown as below figure. HART communicates at 1200 bps without interrupting and interference with the 4-20mA signal and allows a host application (master) to send/receive digital information from a smart field device. The 4-20mA signal communicates the primary measured value - the fastest and most reliable industry standard. The digital signal can be used for additional device information including device status, diagnostics, additional measured or calculated values, etc. Therefore, the HART communication including analog and digital information provides a low-cost and very robust complete field communication solution that is easy to use and configure. HART is a master/slave protocol which provides for up to two masters (primary and secondary) and the secondary master such as handheld can be used to monitor/control the informatoin of HART bus. HART can be used in various modes such as point-to-point or multi-drop for communicating information to/from smart field instruments and central control or monitoring systems. The following are the description of two main HART operation modes.

  • Relatively easy to understand and use, the HART protocol provides access to the wealth of additional information (variables, diagnostics, calibration, etc.)
  • HART is a no risk solution for enhanced field communication
  • Compatibility with standard 4-20mA wiring
  • Simultaneous transmission of digital data
  • Risk reduction through a highly accurate and robust protocol
  • Increase Plant Availability
  • Reduce Maintenance Costs
  • Improve regulatory compliance

Utitlity

  • Provide the system and communication configuration of HRT-711
  • Provide the Modbus address table for HART command data
  • Provide the diagnostic information of HRT-711 module and HART device
  • Provide send / receive HART command to access HART device
  • Provide "Load/Save" module configuration file to apply to other HRT-711 quickly

Modbus Support

Code name Description
01 Read Coil Status Read the ON/OFF status of discrete outputs in the slave
02 Read Input Status Read the ON/OFF status of discrete inputs in the slave
03 Read Holding Registers Read the binary contents of holding registers in the slave
04 Read Input Registers Read the binary contents of input registers in the slave
05 Force Single Coil Write a single output in either ON or OFF in the slave
06 Preset Single Register Write an integer value into a single register in teh slave
15 Force Multi. Coils Write each coil in teh sequence of coils to either ON or OFF in the slave
16 Preset Multi. Registers Write a block of contiguous registers in the slave

Specifications

Ethernet Interface
Controller 10/100Base-TX Ethernet Controller (Auto-negotiating, Auto_MDIX)
Connector RJ-45 x 1 (LED)
UART Interface (For Configuration
COM Port RS-232 (3 wires)
Connector 3-pin screwed terminal block
HART Interface
HART Channel 1
HART Interface 2-pin screwed terminal block
HART Device 2-wired or 4-wired HART devices
HART Topology Point to Point or Multi-Drop
HART Data Only Digital Data
HART Frame Type Short and Long Frame
Burst Mode Supported
Max. HART Device 15
Loop Resistor 250 Ω resistor by Jumper
Isolation UL1577 Spec.
Power
Power Supply Unregulated +10 ~ +30 VDC
Protection Power reverse polarity protection, Over-voltage brown-out protection
Power Consumption 1 W
Mechanism
Installation DIN-Rail or Wall Mounting
Dimensions 72 mm x 35 mm x 121 mm (W x L x H) Detail
Environment
Operating Temperature -25 ℃ ~ +75 ℃
Storage Temperature -30 ℃ ~ +85 ℃
Humidity 5% ~ 95% RH, non-condensing

References and Support

Customer Reviews (1)

March 24, 2016
Leslie L.
5/5

We are using it to connect with our flow meters for our gas monitoring applications. They are durable and fast. Plus the customer service of ICP is great! Thanks team.


Recently Viewed Items

×

Write a Review

Name


E-mail


Phone


Rating: out of 5 Stars
Review (max 1000 characters)

characters left