3 Phase/4 Loops 1 Phase Compact Smart Power Meter communicable over Modbus RTU or CANbus. Supports input types:  Vrms, Irms, kW, kWh, kVA, kVAh, kVAR, kVARh, and PF.

PM-213x

3 Phase/4 Loops 1 Phase Compact Smart Power Meter communicable over Modbus RTU or CANbus. Supports input types: Vrms, Irms, kW, kWh, kVA, kVAh, kVAR, kVARh, and PF.

    Item Not Available  


Features

*** The PM-2xxx series has been phased out and replaced with the PM-3xxx series ***

It's always difficult but crucial to the supervisors to figure out how much energy is consuming. ICP DAS brings the most powerful, cost effective, advanced Compact Power Meters, PM-213X series, to the markets.

With its high accuracy (1%, PF=1), the PM-213x series products can be applied both on low voltage primary side and/or medium/high voltage secondary side and enable the users to obtain in real time the reliable and accurate energy consumption readings from the monitored equipments while in operation. These compact size and cost effective Power Meters are equipped with revolutionary wired clip-on CT (various types support input current up to 200A) and standard Modbus communication RS-485 protocol for easy deployment. It works with input voltages ranging 10V ~ 500V, supporting a wide range of applications.

ICP DAS offers PM-213X family in a full range of Single-phase and Three-phase compact power meters for power monitoring. The products offer a rich feature set combined with easy-to-integrate communications.


  • True RMS energy and power parameters measurement in compact size.
  • Easy wiring for on-line installation.
  • RS-485 communication supported Modbus RTU protocol , CAN Bus Communication supported Compatible with CAN specification 2.0B.
  • Wh accuracy better than 1%(PF=1).
  • With wired clip-on CT (various types support input current up to 200A).
  • LED pulse output.

Power Meter Selection Guide:


power meter types

Specifications

Model PM-2134 PM-2133
Input Voltage 10 - 300 V 10 - 500 V
Input Current CT Φ10 mm (60 A), CT Φ16 mm (100 A), CT Φ24mm (200 A)
Aux Power DC 10 - 30 V
Frequency 60/50 Hz
Starting I <0.025A
Wiring diagram 1-phase 4-channel Auto or manual setting 1P2W-1CT, 1P3W-2CT, 3P3W-2CT, 3P3W-3CT, 3P4W
Power Parameters Measures V1, V1, V2, V2
I 1, I 2, I 3, I 4
kW1, kW2, kW3, kW4
kVA1, kVA2, kVA3, kVA4
kvar1, kvar2, kvar3, kvar4
PF1, PF2, PF3, PF4
kWh1, kWh2, kWh3, kWh4
kVAh1, kVAh2, kVAh3, kVAh4
kvarh1, kvarh2, kvarh3, kvarh4
VA, VB, VC, Vave
I A, I B,I C, I ave
kWA, kWB, kWC, kWtot
kVAA, kVAB, kVAC, kVAtot
kvarA, kvarB, kvarC, kvartot
PFA, PFB, PFC, PFtot
kWhA , kWhB, kWhC, kWhtot
kVAhA , kVAhB, kVAhC, kVAhtot
kvarhA , kvarhB, kvarhC, kvarhtot
Communication RS485, half duplex isolated
Baud Rate:9600, 19200, 38400
Protocol:Modbus-RTU
kWh Accuracy 0.1%(PF=1) better than IEC62053-21
Dimension 78(L) × 35(W) × 99(H) mm
Operating Temperature -10 °C ~ 70 °C
Installation Rail-mounted

Installs Simple Clip-on CT

Clip-on CT

Wiring Diagram

Wiring Diagram

Model Explanation

PM-2133: 3 Phase Compact Smart Meter

PM-213x

PM-2134: 4 Loops 1 Phase Compact Smart Meter

PM-2134

CT Size (measurement) Explanation

100: CTΦ10mm (0~60A)

CT01

160: CTΦ16mm (0~100A)

CT02

240: CTΦ24mm (0~200A)

CT03

Selection Guide

Selection Guide

References and Support

Customer Reviews (0)

Be the first to leave a review.

Recently Viewed Items

×

Write a Review

Name


E-mail


Phone


Rating: out of 5 Stars
Review (max 1000 characters)

characters left