High Performance Intelligent USB to 2-port CAN Converter. Supports operating temperatures between -25 to 75°C.

I-7565-H2

High Performance Intelligent USB to 2-port CAN Converter. Supports operating temperatures between -25 to 75°C.

  Price:  $429.00  

Fastest Delivery: (Details) X Delivery Details
We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

Features

I-7565 H2I-7565-H1 and I-7565-H2 are the high performance intelligent USB to CAN converters with one and two CAN channels separately. They provide faster CAN bus communication performance than I-7565. Both I-7565-H1 and I-7565-H2 support CAN2.0A/2.0B protocol and different baud rates from 5 Kbps to 1 Mbps. The important feature of I-7565-H1/H2 is to support the user-defined baud rate function no matter what the baud rate is. When connecting I-7565-H1/H2 to PC, PC will load the relevant device driver automatically (hot plug & play). Therefore, users can make data collection and processing of CAN bus network easier and quicker by applying I-7565-H1/H2. The application fields can be CAN bus monitoring, building automation, remote data acquisition, environment control and monitoring, laboratory equipment & research, factory automation, etc.

The following is the application structure for these two USB/CAN modules. The PC can be the CAN host, monitor or HMI to access/control the CAN device through the CAN network by the I-7565-H1/H2 Converter. These modules let users to communicate with CAN devices easily from PC with USB interface.
(1) I-7565-H1: High Performance intelligent USB to 1- port CAN bus Converter.
(2) I-7565-H2: High Performance intelligent USB to 2- port CAN bus Converter.

i7565 H1 application
I-7565-H2 Application
i7565 H2 application
I-7565-H1 Application

2500Vrms isolation on CAN side
The CAN port of I-7565-H1/H2 is isolated with 2500Vrms. This isolation can protect the local devices from the damage signal coming from CAN network.

Watchdog inside
The I-7565-H1/H2 Watchdog is a hardware reset circuit to monitor the operation status of I-7565-H1/H2. When working in a harsh or noisy environment, the I-7565-H1/H2 may be down by the external signal. The circuit may let the I-7565-H1/H2 work continuously and never halt.

Power / Communication / Error indicator display
There are three indicators on the I-7565-H1/H2.The power indicator can help user to check whether the I-7565-H1/H2 is standby. The communication indicator is used to show whether the I-7565-H1/H2 is transmitting/receiving messages. The Error indicator will be turned on when some errors occur on the I-7565-H1/H2.

Specifications

  • RoHS Design
  • Fully compliant with USB 1.1/2.0(Full Speed)
  • Fully compatible with the ISO 11898-2 standard
  • Support both CAN2.0A and CAN2.0B
  • No external power supply (powered by USB)
  • Integrated with one or two CAN bus channels
  • Programmable CAN bus baud rate from 5Kbps to 1Mbps or user-defined baud rate
  • Support CAN bus acceptance filter configuration
  • Time-stamp of CAN message with at least ¡Ó1ms precision
  • Support firmware update via USB
  • Provide utility tool for users module setting and CAN bus communication testing conveniently
  • Provide API library for users' program development easily
  • Provide PWR / RUN / ERR indication LED
  • Built-in jumper to select 120 ohm terminal resister
  • Max data flow for CAN Channel: 3000 fps ( depends on users¡¦ PC hardware performance )
  • The CAN buffer is 256 data frames for I-7565-H1 and 128 data frames in each CAN port for I-7565-H2.
  • Watchdog inside
  • Driver supported for Windows 2000/XP, Linux and WinCE (available soon)
  • Factory Automation
  • Building Automation
  • Home Automation
  • Control System
  • Monitor System
  • Vehicle Automation

 

  • Provide CAN bus user-defined baud rate / acceptance filter configuration
  • Easily transmit/receive CAN messages for testing and display the time-stamp of each received CAN message.
  • Provide saving the CAN message as “TXT” file for data log.
  • Provide sending CAN message by using the internal timer of module for high precision transmission.
  • Check / Reset module status remotely and get current CAN bus message flow.
  • Users can develop own program by API library quickly and easily.

a

 

Item
I-7565-H1
I-7565-H2
Hardware
CAN Port Channels
1
2
CAN Interface
Controller
Microprocessor inside with 72MHz
Microprocessor inside with 72MHz
Transceiver
NXP 82C250
NXP 82C250
Connector
9-pin D-sub connector
10-pin terminal-block connector
Baud Rate (bps)
5K ~ 1Mbps or User-defined baud rate
5K ~ 1Mbps or User-defined baud rate
Isolation
3000VDC for DC-to-DC
2500Vrms for photo-couple
3000VDC for DC-to-DC
2500Vrms for photo-couple
Terminator Resistor
Selectable 120Ω terminator resistor by jumper
Selectable 120Ω terminator resistor by jumper
Specification
ISO-11898-2, CAN 2.0A and CAN 2.0B
ISO-11898-2, CAN 2.0A and CAN 2.0B
Pin Assignment
C.I.A. DS-102 (CAN_H=7, CAN_L=2)
(CAN1: CAN_H=4, CAN_L=2 ) / 
(CAN2: CAN_H=9, CAN_L=7 )
Receive Buffer
256 data frames
128 data frames for each CAN port
Max Data Flow
3000 fps
3000 fps (Total CAN ports)
USB Interface
Connector
USB Type B
USB Type B
Transmission speed
12M kbps
12M kbps
Specification
USB 1.1 and USB 2.0 standard
USB 1.1 and USB 2.0 standard
Receive Buffer
100 data frames
100 data frames
LED
Round LED
PWR / RUN /ERR LED
PWR / RUN /ERR LED
Software
Driver
Windows 2K/XP, Linux
WinCE (available soon)
Windows 2K/XP, Linux
WinCE (available soon)
Power
Power supply
By USB interface
By USB interface
Power Consumption
1.5 W
1.5 W
Dip Switch
Init (Firmware Update) / 
Normal (Firmware Operation)
Init (Firmware Update) / 
Normal (Firmware Operation)
Mechanism
Installation
DIN-Rail
DIN-Rail
Dimensions
108mm x 72mm x 35mm (H x W x D)
108mm x 72mm x 35mm (H x W x D)
Environment
Operating Temp.
-25 ~ 75 ℃
-25 ~ 75 ℃
Storage Temp.
-40 ~ 80 ℃
-40 ~ 80 ℃
Humidity
5 ~ 95% RH, non-condensing
5 ~ 95% RH, non-condensing
 
 