Download Now

Enter your information or login to view the document.


×
3-Phase Smart Power Meter (60A).  Voltage Measurements Up to 500V with CAN bus interface.  Has 2-Power Relay Output (Form A). -10 °C ~ +70°C (+14°F ~ 158°F) operating temperatures.

PM-3133-240-CAN

3-Phase Smart Power Meter (60A). Voltage Measurements Up to 500V with CAN bus interface. Has 2-Power Relay Output (Form A). -10 °C ~ +70°C (+14°F ~ 158°F) operating temperatures.

    Item Not Available  


Features

Application Image PM-3133-240-CANICP DAS offers PM-3133 family in a full range of Single-phase and Three-phase smart power meters for power monitoring. The products offer a rich feature set combined with easy-to-integrate communications. With its high accuracy (<0.5%, PF=1), the PM-3133 series products can be applied both on low voltage primary side and/or medium/high voltage secondary side and enable the users to obtain in real time the reliable and accurate energy consumption readings from the monitored equipments. These compact size and cost effective Power Meters are equipped with wired clip-on CT (supports input current up to 200A) and standard Modbus communication RS-485 protocol for easy deployment. It works with input voltages ranging from 10V ~ 500V, supporting a wide range of applications.

  • True RMS energy and power parameters measurement.
  • Energy Analysis for 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
  • Current Measurements Up to 200A with Different CT Ratio
  • Voltage Measurements Up to 500V
  • Clip-on CT for Easy Installation
  • W Accuracy Greater than 0.5% (PF=1)
  • Supports 2-Power Relay Output (Form A)

Specifications

Model PM-3133-240-CAN
AC Power Measurement
Wiring 1P2W-1CT, 1P3W-2CT, 3P3W-2CT, 3P3W-3CT and 3P4W-3CT
Measurement Voltage 10 ~ 500 V (CAT III)
Measurement Current CT Φ10 mm (60 A); CTΦ16 mm (100 A); CTΦ24 mm (200 A)
Measurement Frequency 50-60 Hz
W Accuracy Greater than 0.5% (PF=1)
Starting Current >0.03A ( 60A ), >0.05A (100A ), >0.09A( 200A )
Power Parameter Measurement True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW),
Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh),
Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Data Update Rate 1 Second
Communication
Dimension Protocol -
Baud rate -
Data forat -
Isolation -
Bias Resistor -
Ethernet Protocol -
CAN Bus Protocol CAN and CANopen
Baud Rate 125 k (default), 250 k, 500 k, 1 M;
DIP Switch Selectable
Isolation 2500 VDC
Alarm Output
Power Relay Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250
VAC (47 ~ 63Hz), 5 A @ 30 VDC
Aux Power
Input Range +12 ~ 48 VDC or PoE
Power Consumption 4 W
Dimensions (W x L x H) 127 mm x 105 mm x 33 mm
Environment
Operating Temperature -10 ~ +70 °C (14 °F ~ 158 °F)
Storage Temperature -25 ~ +80 °C (-13° F ~ 176° F )