Modbus RTU Based Data Acquisition Module With 6 Analog Inputs, Current Input (±150mV, ±500mV, ±1V, ±5V, ±10V, ±20mA, 0-20mA, 4-20mA), 2 Analog Outputs, 3 Digital Inputs (with Counter) and 3 Digital Outputs.  Supports Operating Temp Between -25°C  ~ +75°C (-13°F ~ +167°F).

M-7026

Modbus RTU Based Data Acquisition Module With 6 Analog Inputs, Current Input (±150mV, ±500mV, ±1V, ±5V, ±10V, ±20mA, 0-20mA, 4-20mA), 2 Analog Outputs, 3 Digital Inputs (with Counter) and 3 Digital Outputs. Supports Operating Temp Between -25°C ~ +75°C (-13°F ~ +167°F).

  Price:  $529.00  

Fastest Delivery: (Details) X Delivery Details
We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

Features

m-7026 application

The M-7026 is a Modbus RTU based multifunction module  with 6 analog inputs, 2 analog outputs, 3 digital inputs, and 3 digital outputs . It provides a programmable input range on all analog inputs (+/-150 mV, +/-500 mV, +/-1 V, +/-5 V, +/-10 V, +/-20 mA or 0 ~ +20 mA).  The analog outputs are 12-bit at +/-5 V, +/-10 V, 0 ~ +20 mA or +4 ~ +20 mA.  All digital outputs can be set as alarm outputs. Each analog input can be configured for an individual range and provides a high overvoltage protection of 240 Vrms. Voltage and current inputs/outputs are jumper selectable.

  • Multifunction (6 AI, 2 AO, 3 DI and 3 DO)
  • Supports Fast Mode and Normal Mode
  • Individual Channel Configuration
  • Open Wire Detection for Current Output
  • Overload and Short Circuit Protection for Digital Output
  • Configurable Power-on Value Settings
  • Configurable Safe Value Settings
  • Supports Modbus RTU Protocol
  • 240 Vrms Overvoltage Protection for Voltage Input
  • Jumper Selectable Voltage or Current Input/Output
  • Dual Watchdog
  • ±4 kV Contact ESD Protection
  • Wide Operating Temperature Range: -25 ~ +75°C

 

Applications:

  • Industrial Automation
  • Building Automation
  • Food and Beverage Systems
  • Semiconductor Fabrication
  • Control Systems
  • Industrial Machinery

Specifications

Analog Input
Channels 6
Wiring Differential
Range ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V
±20 mA , 0 ~ 20 mA, 4 ~ 20 mA(Jumper Selectable)
Resolution 16-bit
Accuracy Normal Mode ±0.1% of FSR
Fast Mode ±0.5% or better
Sampling Rate Normal Mode 10 Samples/Sec.
Fast Mode 60 Samples/Sec. (Total)
Bandwidth Normal Mode 15.7 Hz
Fast Mode 78.7 Hz
Input Impedance Voltage 2 MΩ
Current 140 Ω
Common Voltage Protection ±200 V 
Individual Channel Configuration Yes
Overvoltage Protection 240 Vrms
Overcurrent Protection Yes, 50 mA at 110 VDC
Virtual Channel to Channel Isolation Yes,400 VDC
Open Wire Detection for 4 ~ 20 mA Yes
Analog Output
Channels 2
Range +0 ~ +5 VDC, +0 ~ +10 VDC, ±5 VDC, ±10 VDC,
+0 ~ +20 mA, +4 ~ +20 mA (Jumper Selectable)
Resolution 12-bit
Accuracy ±0.1% of FSR
Output Capacity
Voltage Output Capability
10 V @ 20 mA
Open Wire Detection Yes, for 4 ~ 20 mA only
Power-on Value Yes, Programmable
Safe Value Yes, Programmable
Digital Input/Counter
Channels 3
Type Dry Contact Source
Wet Contact -
Wet Contact On Voltage Level -
Off Voltage Level -
Dry Contact On Voltage Level Close to GND
Off Voltage Level Open
Counters Max. Count 65535 (16-bit)
Max. Input Frequency 100 Hz
Min. Pulse Width 5 ms
Input Impedance -
Channel-to-Channel Isolation -
Overvoltage Protection -
Safe Value Yes, Programmable
Digital Output
Output Channels 3
Type Open Collector
Sink/Source (NPN/PNP) Sink
Load Voltage + 3.5 VDC ~ + 50 VDC
Max. Load Current 700 mA/Channel
Overvoltage Protection 60 VDC
Overload Protection Yes
Short-circuit Protection Yes
Power-on Value Yes, Programmable
Safe Value Yes, Programmable

 

 

Communication
Interface RS-485
RS-485 Bias Resistor No (An RS-485 master is required to provide the bias.)
Format N, 8, 1
Baud Rate 1200 ~ 115200 bps
Protocol Modbus RTU, DCON
Dual Watchdog Yes, Module (1.6 Seconds), Communication (Programmable)
LED Indicators/Display
System LED Indicator Yes, 1 LED as Power/Communication Indicator
I/O LED Indicators -
7-Segment LED Display - 
Isolation
Intra-module Isolation,
Field-to-Logic
2500 VDC
EMS Protection
ESD (IEC 61000-4-2) ±4 kV Contact for each Terminal
±8 kV Air for random point
EFT (IEC 61000-4-4) ±4 kV for Power Line
Surge (IEC 61000-4-5) ±3 kV for Power Line
Power
Reverse Polarity Protection Yes
Input Range 10 ~ 30 VDC
Consumption 1.8 W
Mechanical
Dimensions (W x L x H) 72 mm x 123 mm x 35 mm

References and Support

Customer Reviews (1)

November 30, -0001
Rex L.
5/5

We've been using this unit for years and they worked great in our application! ICP DAS never disappoints us.