Download Now

Enter your information or login to view the document.


×
6-channel RTD Analog Input Module with 3-wire RTD lead resistance elimination. Supports RTD types of Pt100, Pt1000, Ni120, Cu100, and Cu1000. Communicable over Modbus RTU and RS-485. Supports operating temperatures between -25 to 75°C (-13F ~ 167F).

M-7015P

6-channel RTD Analog Input Module with 3-wire RTD lead resistance elimination. Supports RTD types of Pt100, Pt1000, Ni120, Cu100, and Cu1000. Communicable over Modbus RTU and RS-485. Supports operating temperatures between -25 to 75°C (-13F ~ 167F).

  Price:  $589.00  

Fastest Delivery: (Details) X Delivery Details
We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

Features

The I-7000 series is a family of network data acquisition and control modules, providing analog-to-digital, digital-to-analog, digital input/output, timer/counter and other functions. The modules can be remotely controlled using a set of commands, which we call the DCON protocol. Communication between the module and the host is in ASCII format via an RS-485 bi-directional serial bus standard. Baud Rates are software programmable and transmission speeds of up to 115.2 Kbps can be selected.

The functionality of the M-7000 series is the same as the I-7000 series, with the exception that the M-7000 series offers extended support for the Modbus RTU protocol. Some I-7000 modules feature a new design for the frame ground and INIT switch as shown in the figure (rear view). The frame ground provides enhanced static protection (ESD) abilities and ensures the module is more reliable. The INIT switch allows easier access to INIT mode.

The common features of the I-7013/13D, I-7033/33D, I-7015/15P, M-7015/15P, and M-7033/33D modules are as follows:

  1. 3000V DC inter-module isolation
  2. 24-bit sigma-delta ADC to provide excellent accuracy
  3. Direct RTD (resistance temperature detector) connection
  4. Software calibration

The I-7015/M-7015 is a 6-channel RTD input module. The I-7015P/M-7015P is a 6-channel RTD input module with lead resistances elimination.

Supported RTD types are as follows:

  1. 1. Platinum, 100 Ohms at 0°C, α= 0.00385
  2. Platinum, 100 Ohms at 0°C, α= 0.003916
  3. Platinum, 1000 Ohms at 0°C, α= 0.00385 (I-7013/13D firmware version B1.3 and later, I-7033/33D, M-7033/33D, I-7015/15P and M-7015/15P)
  4. Nickel, 120 Ohms at 0°C, α= 0.00672
  5. Copper, 100 Ohms at 0°C, α= 0.00421 (I-7015/15P and M-7015/15P)
  6. Copper, 1000 Ohms at 0°C, α= 0.00421 (I-7015/15P and M-7015/15P)
  7. Copper, 100 Ohms at 25°C, α= 0.00427 (I-7015/15P and M-7015/15P)
  8. Copper, 50 Ohms at 0°C, (I-7015/15P and M-7015/15P firmware version A2.3 and later)
  9. Nickel, 100 Ohms at 0°C, (I-7015/15P and M-7015/15P firmware version A2.9 and later)

Specifications

Analog Input
Input Channels 6
Input Type RTD
Wire connection 2/3 wire
RTD Type Pt100, Pt1000, Ni120, Cu100, Cu1000
Resolution 16-bit
Sampling Rate 12 samples/ second (Total)
Accuracy +/-0.05%
-3dB BandWidth 5.24Hz
Zero drift +/-20uV/°C
Span drift +/-25ppm/°C
Common Mode Rejection Typical 86dB
Normal Mode Rejection 100 dB
Voltage Input Impedance >1M Ohms
Open Wire Detection Yes
Individual Channel Configurable Yes
3-wire RTD lead resistance elimination Yes
ESD Protection 4KV Contact for each terminal, and 8KV Air for random point
EFT Protection 4KV to Power, and 1KV to RS-485
Intra-module Isolation, Field to Logic 3000 VDC
Interface
Interface Modbus RTU, RS-485
Format N, 8, 1
Baud Rate 1200 ~ 115200bps
LED Display
1 LED as Power/ Communication indicator
Power
Input +10 to +30 Vdc
Power Consumption 1.2W
Protocol
Support Modbus and DCON Protoco Yes
Watchdog Yes, Module, Communication (Programmable over DCON) frmware version B202 and later
Environment
Operating temperature -25 to 75°C
Storage temperature -40 to 85°C
Humidity 5 to 95% RH, non-condensing

RTD Type Setting

Type Code RTD Type Temperature Range °C
20 Platinum 100, α= 0.00385 -100 ~ 100
21 Platinum 100, α= 0.00385 0 ~ 100
22 Platinum 100, α= 0.00385 0 ~ 200
23 Platinum 100, α= 0.00385 0 ~ 600
24 Platinum 100, α= 0.003916 -100 ~ 100
25 Platinum 100, α= 0.003916 0 ~ 100
26 Platinum 100, α= 0.003916 0 ~ 200
27 Platinum 100, α= 0.003916 0 ~ 600
28 Nickel 120 -80 ~ 100
29 Nickel 120 0 ~ 100
2A Platinum 1000, α= 0.00385 -200 ~ 600
2B Cu 100 at 0°C,α= 0.00421 -20 ~ 150
2C Cu 100 at 25°C,α= 0.00427 0 ~ 200
2D Cu 1000 at 0°C,α= 0.00421 -20 ~ 150
2E Platinum 100, α= 0.00385 -200 ~ 200
2F Platinum 100, α= 0.003916 -200 ~ 200
80 Platinum 100, α= 0.00385 -200 ~ 600
81 Platinum 100, α= 0.003916 -200 ~ 600
82 Cu 50 at 0°C -50 ~ 150
83 Nickel 100 -60 ~ 180

References and Support

Customer Reviews (0)

Be the first to leave a review.

Recently Viewed Items

×

Write a Review

Name


E-mail


Phone


Rating: out of 5 Stars
Review (max 1000 characters)

characters left