Download Now

Enter your information or login to view the document.


×
CAN to Ethernet / Modbus TCP / Modbus RTU Converter. Supports operating temperatures between -25 to 75°C.

I-7540D-MTCP

CAN to Ethernet / Modbus TCP / Modbus RTU Converter. Supports operating temperatures between -25 to 75°C.

  Price:  $759.00  

Fastest Delivery: (Details) X Delivery Details
We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

Features

I-7540D-MTCP is a CAN to Ethernet / Modbus TCP / Modbus RTU Converter. It is helpful for exchanging data between Modbus devices and CAN devices. I-7540D-MTCP is a Modbus TCP server and acts as slave device in Modbus RTU networks. It supports four communication modes: Modbus TCP, Modbus RTU, CAN-Ethernet Conversion and Pair connection.

The major function of the I-7540D-MTCP is a CAN to Modbus TCP/RTU gateway. It allows Modbus TCP/RTU devices to communicate with CAN devices on a CAN network. I-7540D-MTCP supports the function codes 0x03/0x04/0x10 of Modbus TCP/RTU for reading and writing of CAN messages. The device supports a transparent, protocol-independent transfer of the CAN messages, thus allowing its implementation into a wide range of possible applications. The CAN-Modbus Converter can be used with various higher layer CAN protocols (e.g. CANopen, DeviceNet or other proprietary protocols). These application diagrams show the application architecture for the I-7540D CAN-Modbus Converter.
Modbus TCP / RTU to CAN
Modbus TCP / RTU to CAN

  • Features:
    • 80186-80 Embedded CPU, or compatible
    • Ethernet Protocols, TCP,UDP,IP,ICMP,ARP
    • COM driver support interrupt & 1K QUEUE Input & Output buffer
    • Provide 200 CAN frames buffer in CAN to Modbus Mode
    • NXP 82C 250 CAN Transceiver
    • Support both CAN specification 2.0A and 2.0B
    • Max transmission speed up to 1M bps for CAN and 115.2kbps for RS-232 & RS-485
    • Max transmission distance of CAN over 1000m (follow CAN specification)
    • 7-segment LED display to Module IP, RS-232 baud rate, CAN configuration…
    • CAN Error/Tx/Rx LED indicator
    • Software configurable CAN and RS-232 communication parameters
    • Firmware updated from COM1 or Ethernet port
    • Support Web Configuration
    • Support maximum 24 Ethernet clients connection
    • Support function code 0x03/0x04/0x10 of Modbus TCP/RTU command for reading and writing CAN message
    • Provide the transparent communication between the CAN devices via Ethernet
    • Support 30 specific CAN IDs in the Modbus TCP/RTU mode

  • Applications:
    • Factory Automation
    • Building Automation
    • Home Automation
    • Control Systems
    • Monitoring Systems
    • Vehicle Automation


  • CAN bus Power Meter Solution
    • The PM-213x-CAN series power meter provides the CAN bus interface for users to easily gather the real-time power consumption information in their CAN applications. The PM-213x-CAN provides the Auto-Response mode which responses messages at regular intervals automatically. It makes the communication more efficient when collecting a lot of remote power information. The polling mode offers the precise information of every step required by the monitors. In addition, the PM-213x-CAN also owns the arbitration mechanism which can avoid data collision and error detection.
      CAN Power Meter

  • Utility:
    • Operation mode configuration
    • IP 、 Gateway 、 Mask configuration
    • CAN bus Baud rate configuration
    • CAN BTR0 and BTR1 configuration
    • CAN acceptance filter configuration
    • CAN 2.0A or 2.0B specific selection
    • Error code Responded selection
    • Easy test to transmit/receive CAN messages
    • Easy test to Modbus TCP/Modbus RTU command

Specifications

CAN Interface
Controller
NXP SJA1000T with 16 MHz clock
Transceiver
NXP 82C250
Channel number
1
Connector
2-pin screwed terminal block (CAN_L, CAN_H)
Baud Rate (bps)
10 k, 20 k, 50 k, 125 k, 250 k, 500 k, 800 k, 1 M (allow user-defined baud rate)
Isolation
1000 VDC for DC-to-DC, 2500 Vrms for photocoupler
Terminator Resistor
Jumper for 120 Ω terminator resistor
Specification
ISO-11898-2, CAN 2.0A and CAN 2.0B
UART Interface
COM 1
RS-232
COM 1 Connector
5-pin screwed terminal block (TxD, RxD, RTS, CTS, GND )
COM 2
RS-485 (Self-turner inside)
COM 2 Connector
2-pin screwed terminal block (DATA+, DATA-)
Baud Rate (bps)
110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
Data bit
7, 8
Stop bit
1
Parity
None, Even, Odd
Ethernet Interface
Controller
10/100Base-TX Ethernet Controller (Auto-negotiating, Auto_MDIX)
Connector
RJ-45 with LED indicator
Power
Power supply
Unregulated +10 ~ +30 VDC
Protection
Power reverse polarity protection, Over-voltage brown-out protection
Power Consumption
2.5 W
Mechanism
Installation
DIN-Rail
Dimensions
72mm x 122mm x 33mm (W x L x H)
Environment
Operating Temp.
-25 ~ 75 °C
Storage Temp.
-30 ~ 80 °C
Humidity
10 ~ 90% RH, non-condensing

References and Support

Customer Reviews (0)

Be the first to leave a review.

Recently Viewed Items

×

Write a Review

Name


E-mail


Phone


Rating: out of 5 Stars
Review (max 1000 characters)

characters left