Download Now

Enter your information or login to view the document.


×
RS-232/485/422 to CAN Converter with Software Utility.  Supports operating temperatures between -25 to 75°C.

I-7530A

RS-232/485/422 to CAN Converter with Software Utility. Supports operating temperatures between -25 to 75°C.

  Price:  $449.00  

Fastest Delivery: (Details) X Delivery Details
We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

Features

I-7530 diagramCAN (Controller Area Network) is a serial bus control protocol especially suited to structure intelligent industry devices networks and build smart automatic control systems. By using I-7530, some programmable RS-232 devices such as PC, I-8411/I-8431/I-8811/I-8831 embedded controllers, can be the master of a CAN network. Therefore, they can control or monitor the CAN devices via the I-7530 module. The I-7530A is designed to unleash the power of CAN bus via RS-232/485/422 communication method. It accurately converts messages between CAN and RS-232/485/422 networks. This module let you to communicate with CAN devices easily from any PC or devices with RS-232/485/422 interface.





Moreover, we expand the functionalities of I-7530A for some special application. In pair connection mode, I-7530A can be used to connect PC with other RS-232/485/422 devices at the same time. The application architecture may be as follows.

application 2

3000V isolation on CAN side
The CAN port of I-7530A is an isolated with 3000V isolation. This isolation can protect the local RS-232/485/422 devices from the damage signal coming from CAN network.

Watchdog inside
The I-7530A Watchdog is a hardware reset circuit to monitor the I-7530A’s operation status. When working in harsh or noisy environment, the I-7530A may be down by the external signal. The circuit may let the I-7530A to work continuously and never halt.

Power and Error indicator display
There are two indicators on the I-7530A.The power indicator can help user to check whether the I-7530A is standby or transmitting/receiving messages. The Error indicator will be turned on when some errors occur on the I-7530A.

  • Microprocessor inside with 20MHz
  • CAN interface connector: D-Sub 9-pin
  • 82C250 CAN transceiver
  • Built-in CAN/RS-232/485/422 Converter firmware
  • Max transmission speed up to 1M bps for CAN and 115.2K bps for RS-232/485/422
  • Software configurable CAN and RS-232/485/422 communication parameters
  • Max transmission distance over 1000m (follow CAN specification)
  • Support both CAN 2.0A and CAN 2.0B
  • Built-in jumper to select 120 ohm terminal resister
  • Mount easily on DIN-rail
  • Power, data flow and error indicator for CAN and RS-232/485/422
  • Watchdog inside
  • Support transparent communication mode
  • Provide the transparent communication between the RS-232/485/422 devices via CAN bus.
  • Enable different RS-232/485/422 devices into an individual group in CAN bus network.
    (Full-duplex communication mode of RS-232/422 devices is not supported)
  • I-7530A Software Utility Features
    • CAN bus Baud rate configuration
    • CAN acceptance filter configuration
    • CAN 2.0A or 2.0B specific selection
    • RS-232/485/422 Baud rate and data bit setting
    • RS-232/485/422 responded selection
    • Easy test to transmit/receive CAN messages
    • Setting for I-7530A communication mode (normal mode or pair connection mode)
  • CAN Monitor and Datalog Tool
    • It has a CAN message field which can display the receiving CAN messages in Decimal or HEX mode.
    • Can display the timestamp of each received CAN message.
    • Users can change the display mode, up-down, down-up or stop.
    • It can count the number of received CAN messages.
    • Data Log : It can save the CAN message as “ txt ” file.
    • Has CAN ID filter function.
    • Can send CAN message to CAN BUS according the defined interval time.
    • application 2
  • Applications
    • Control Systems
    • Building Automation
    • Factory Automation
    • Distributed data acquisition
Performance Test: Transfer 8 bytes data frame from CAN to RS232
CAN setting Transfer frames Transfer time(ms) RS-232 setting Receive frames Receive time (ms) The max frames/sec Data<8 byes/frme RS232 command length
2.0A 1Mbps 1,000 200 115200,n,8,1 1,000 2954 338 >=338 22 B
2.0A 1Mbps 1,000 200 115200,n,7,1 1,000 2775 360 >=360 22 B
2.0B 1Mbps 1,000 200 115200,n,8,1 1,000 3580 279 >=279 27 B
2.0B 1Mbps 1,000 200 115200,n,7,1 1,000 3337 299 >=299 27 B

Performance Test: Transfer 8 bytes data frame from RS232 to CAN.
CAN setting Transfer frames Transfer time (ms) RS-232 setting Receive frames Receive time (ms) The max frames/sec Data<8 byes/frame RS232 command length
2.0A 1Mbps 1,000,000 2,612,243 115200,n,8,1 1,000,000 2,612,243 382 >=382 22 B
2.0A 1Mbps 1,000,000 2,441,130 115200,n,7,1 1,000,000 2,441,130 409 >=409 22 B
2.0B 1Mbps 1,000,000 3,142,043 115200,n,8,1 1,000,000 3,142,043 318 >=318 27 B
2.0B 1Mbps 1,000,000 3,142,043 115200,n,7,1 1,000,000 2,966,646 337 >=337 27 B

Specifications

CAN Interface
Controller Multiprocessor inside with 20MHz
Transceiver AMIS 41682
Channel number 1
Connector 9-pin male D-Sub (CAN_L, CAN_SHLD, CAN_H, N/A for others)
Baud Rate (bps) 10 k, 20 k, 50 k, 125 kbps
Terminator Resistor 1 k for CAN_H and CAN_L
Specification ISO-11898-3, CAN 2.0A and CAN 2.0B
Receive Buffer 1000 data frames
UART Interface
COM RS-232
COM Connector 9-pin female D-Sub (DCE: TxD, RxD, GND, N/A for others)
Baud Rate (bps) 110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Data bit 5, 6, 7, 8
Stop bit 1, 2
Parity None, Even, Odd
Receive Buffer 900 data frames
LED
Round LED ON LED: Power and Data Flow; ERR LED: Error
Power
Protection Power reverse polarity protection, Over-voltage brown-out protection
Power Consumption 1 W
Mechanism
Installation DIN-Rail
Dimensions 118mm x 72mm x 33mm
Environment
Operation Temp. -25 ~ 75 C
Storage Temp. -40 ~ 80 C
Humidity 5 ~ 95% RH, non-condensing

References and Support

Customer Reviews (0)

Be the first to leave a review.

Recently Viewed Items

×

Write a Review

Name


E-mail


Phone


Rating: out of 5 Stars
Review (max 1000 characters)

characters left