PROFIBUS to HART Gateway. Communicable over PROFIBUS, HART, RS-232 protocols. Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.

GW-7557

PROFIBUS to HART Gateway. Communicable over PROFIBUS, HART, RS-232 protocols. Supports operating temperatures of -25°C ~ +75°C (-13°F ~ 167°F) and has a din rail mount.

  Price:  $919.00  

Fastest Delivery: (Details) X Delivery Details
We ship via UPS and fastest delivery is with Next Day Air. UPS Next Day Air Early typically gets their product to them as early as 8am, Next Day Air gets their product typically there by 10:30am and Next Day Air Saver typically by 3pm. We ship same day for in stock items and the lead time is up to one week for out of stock items. Delivery is dependent on UPS and your shipping method.
ADD TO CART
ADD TO CART
BUY BY 1-CLICK

Features

The GW-7557 Gateway is specially designed for the slave device of PROFIBUS DP protocol. It allows the PROFIBUS master to access the HART slave devices. These HART slave devices may be a transmitter, an actuator, a current output device and so forth. In addition, we also provide the utility software for users to configure the GW-7557. By using this module, users can put their HART slave devices into PROFIBUS network easily.

gw7557

The HART (Highway Addressable Remote Transducer) protocol uses the Bell 202 Frequency Shift Keying (FSK) standard to superimpose digital communication signals on the 4-20 mA loop current shown as below figure. HART communicates at 1200 bps without interrupting and interference with the 4-20mA signal and allows a host application (master) to send/receive digital information from a smart field device. The 4-20mA signal communicates the primary measured value - the fastest and most reliable industry standard. The digital signal can be used for additional device information including device status, diagnostics, additional measured or calculated values, etc. Therefore, the HART communication including analog and digital information provides a low-cost and very robust complete field communication solution that is easy to use and configure. HART is a master/slave protocol which provides for up to two masters (primary and secondary) and the secondary master such as handheld can be used to monitor/control the informatoin of HART bus. HART can be used in various modes such as point-to-point or multi-drop for communicating information to/from smart field instruments and central control or monitoring systems. The following are the description of two main HART operation modes.

  • Relatively easy to understand and use, the HART protocol provides access to the wealth of additional information (variables, diagnostics, calibration, etc.)
  • HART is a no risk solution for enhanced field communication
  • Compatibility with standard 4-20mA wiring
  • Simultaneous transmission of digital data
  • Risk reduction through a highly accurate and robust protocol
  • Increase Plant Availability
  • Reduce Maintenance Costs
  • Improve regulatory compliance

Applications

  • Industrial Automation
  • Factory Automation
  • Process Automation
  • Etc…

applications

Protocol & Hierarchy
DP-V0 Slave & DP-V1 Slave
Supports PROFIBUS Transmission Rate (kbps)
9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000, 12000
Transmission Rate Setting
detected automatically
Max Input Data Length
240 Bytes
Max Output Data Length
240 Bytes
Address Setting
0~126 set by DIP switch or EEPROM
Supports HART Mode
point-to-point / multi-drop
Support HART Master
Allow two HART Masters
Support HART Channel
4 channels
Support HART Frame
Short/Long frame
Support HART modules
Connecting up to 16 HART modules
Support HART Burst mode
YES
Indicators
PWR, ERR, and RUN LEDs
Network Isolation Protection
2500 Vrms High Speed iCoupler
DC Isolation Protection
3000 VDC on PROFIBUS side

Specifications

Hardware
CPU
80186, 80 MHz or compatible
SRAM/Flash/EEPROM
512 KB / 512 KB / 16 KB
Watchdog
Watchdog IC
CPU built-in
ESD Protection
4 kV class A
PROFIBUS Interface
Controller
Profichip VPC3+C
Transceiver
ADI ADM2486
Connector
9-pin female D-Sub
Baud Rate (bps)
9.6 k, 19.2 k, 45.45 k, 93.75 k, 187.5 k, 500 k, 1.5 M, 3 M, 6 M, 12 M
Transmission Distance (m)
Depend on baud rate (for example, max. 1200 m at 9.6 kbps )
Isolation
3000 VDC for DC-to-DC, 2500 Vrms for bus-to-logic
Protocol
DP-V0 & DP-V1
HART Interface
HART Interface
8-pin screwed terminal block
HART Channel
4 channels
UART Interface
COM
RS-232
COM Connector
3-pin screwed terminal block (RxD, TxD, GND)
Baud Rate (bps)
Up to 115200
Data bit
7, 8
Stop bit
1, 2
Parity
None, Even, Odd
LED
Round LED
PWR LED, RUN LED, ERR LED
POWER
Power supply
Unregulated +10 ~ +30 VDC
Protection
Power reverse polarity protection, Over-voltage brown-out protection
Power Consumption
2.5 W
Mechanism
Installation
DIN-Rail
Dimensions
72 mm x 33 mm x 119 mm (W x L x H)
Environment
Operating Temp.
-25 ~ 75℃
Storage Temp.
-30 ~ 85℃
Humidity
5 ~ 95% RH, non-condensing