Features
The ECAT-2000 is equipped with the EtherCAT protocol and installed by daisy chain connection which permits the flexibility in devices installation and reduces infrastructure and operation costs. The ECAT-2000 modules can be deployed in the network topologies such as star, line or ring. The isolation input and output design protects the ECAT-2000 against the harmful interference and environment.
ICP DAS USA’s ECAT-2011H has 8 built-in isolated differential inputs or 16-ch single-ended inputs by software selectable. Users can obtain the input status via the process data. The ECAT-2011H has passed and verified by the conformance test tool, therefore eligible EtherCAT Master or configurator can manipulate it and implement your applications easily.
- On the fly processing: EtherCAT
- Powerful MCU handles efficient network traffic
- 2 x RJ-45 bus interface
- Distance between Stations up to 100 m (100BASE-TX)
- Support daisy chain connection
- EtherCAT conformance test tool verified
- Removable terminal block connector
- LED indicators
- Built-in Analog Input: 8-/16-ch
- RoHS compliant
- ESD Protection 4 KV Contact for each channel
Applications
- Semiconductor Tools
- Metal Forming
- Packaging
- Injection Molding
- Assembly Systems
- Printing Machines
- Robotics
Specifications
Analog Input
Channels
8/16
Wire Connection
8 Differential or 16 Single-ended (Software Selectable - see Note 1)
Type
Voltage, Current
Range
0~10V, ±10 V, ±5 V, ±2.5 V, 0~ 20 mA, ±20 mA or 4~20mA (Software selectable)
Resolution
12-bit
Sampling Rate
1k Hz per channel
Accuracy
0.2% of FSR
Individual Channel Configuration
Yes
Over Voltage Protection
±35 VDC
Open Wire Detection for +4 ~ 20mA
Yes
Communication Interface
Connector
2 x RJ-45
Protocol
EtherCAT
Distance between Stations
Max. 100 m (100BASE-TX)
Data Transfer Medium
Ethernet/EtherCAT Cable (Min. CAT 5), Shielded
Power
Input Voltage Range
10V ~ 30VDC
Power Consumption
Max. 4W
Mechanism
Installation
DIN-Rail
Dimensions
110mm x 90mm x 33mm (H x W x D, without connectors)
Case Material
UL 94V-0 housing
Environment
Operating Temperature
-25℃ ~ 75℃
Storage Temperature
-30℃ ~ 80℃
Relative Humidity
10 ~ 90%, No Condensation
ESD (IEC 61000-4-2)
4 KV Contact for Each Channel
ESD (IEC 61000-4-2)
Signal: 1 KV Class A; Power: 1 KV Class A
Surge (IEC 61000-4-5)
Signal: 1 KV Class A; Power: 1 KV Class A