DN-843V-600
3-channel 600 V Voltage Attenuator. 0.56 W Power consumption. Has operating temperatures range of -25°C ~ +75°C (-13°F ~ +167°F).
Features
The DN-843V-600V is a voltage input attenuator. The maximum input range is from ±80 V to +/- 600 V and can be attenuated to ±10 V. The "I" version provide 3000VDC intra-modules isolation and 3000VDC channel to channel isolation to avoid the noise interference from inputs to outputs or channel to channel. It can be used with the analog input modules such as I-7017 and I-87017 etc. to measure the high voltage.
- AC/DC Source Input
- High Voltage Input Measurement
- Linear Attenuation Ratio
- High Input Impedance
- Channel to Channel Isolation for DN-848VI-10V,
DN-848VI-80V, DN-848VI-150V and DN-843VI-600V - Channel to Channel Isolation for DN-848VI-10V,
DN-848VI-80V and DN-848VI-150V - 4 kV ESD Protection
- 3 kV Surge Protection
- RoHS Compliance
- Operating Temperature: -25 °C ~ +75 °C
- Easily wire connection
Specifications
General | |
Channels | 3 |
Input Type | AC/DC Voltage |
Input Range | +/- 600 Vpp |
Output Range | +/- 10 Vpp |
Accuracy | 1% of FSR |
Channel to Channel Isolation | - |
Bandwidth | 100 KHz |
Input Impedence | > 1 MΩ |
Intra-module Isolation, Input to Output | – |
EMS Protection | |
ESD (IEC 61000-4-2) | +/- 4 kV contact for power line, input and output channels , +/- 8 kV air for random point |
Surge (IEC 61000-4-5) | +/- 3 kV for power liner |
Power Input | |
Input Range | +10 ~ +24 VDC |
Power Consumption | DIN-Rail Mounting |
Mechanical | |
Dimensions (W x L x H) | 122 mm x 174 mm x 24.5 mm |
Installation | -30°C ~ +75°C (-22°F ~ +167°F) |
Environment | |
Input Range | -25°C ~ +75°C (-13°F ~ +167°F) |
Power Consumption | -30°C ~ +75°C (-22°F ~ +167°F) |
Humidity | 10 ~ 90% RH, Non-condensing |