AD-EZ-SW
Advanced EZ Data Logger: Easy-to-use Data Logging Software for advanced applications with up to 1024 I/O tags.
Features
EZ Data Logger is a small data logger software. It can be applied to small remote I/O system. With its user-friendly interface, users can quickly and easily build a data logger software without any programming skill.
Advanced EZ Data Logger is our Easy to use Data Logging Software for Advanced Applications. It supports up to 1024 I/O tags, 10 SMS or E-mail alarm contacts, up to 10 web cameras, and up to 256 virtual channels.
- Data Logger
- Easy to Use
- Configurable Control and Monitoring Software
- No Programming Needed
- Database Can be Exported to Excel or CVS
- Can Send Alarms by SMS Text Message or Email
Features:
- Supports DCON, Modbus RTU, Modbus Ascii, Modbus TCP(supports IP and Domain name) protocols
- Data logger supports mutiple COM Ports and TCP/IP connections
- Supports Virtual Channel definition
User can operate the data into the virtual channel by channel tag names easily. For example: VC3 = (AI_2 + AI_3) / 2 - Supports Control Logic (VB Script)
User can edit the script to set the output values or to caculate data into virtual channels. You can get/set the channel values by channel tag names. For example : If AI_2 > 50 Then DO_3 = 1 - Supports Alarm Notifier (by sending SMS or E-Mail)
User can set the engineer's cell phone number and email address. When the channel value over the alarm value or back to normal, the contact messanger will send a message by SMS (using GSM Modem with PDU mode supported) or by E-Mail(using ethernet). - Flexible module configuration
Each module and I/O point can have different description and color - Flexible workgroup configuration
Each channel can be assigned to any workgroup. - Real time data trend (with zoom in and zoom out)
Each trend line can store more than 86400 records. - Layout view
User can set back picture and drag-drop I/O points to the mapping place. User can also change the channel layout object as Linear Gauge, Angular Gauge, Toggle, Number LED..... - IP Camera Viewer
User can add an IP camera's web address, and then add it to group. Then the layout display will show the web page in a sub window. - Access database supported
The database also can be exported to Excel file or CVS file - Support Remote SQL Server and MySQL
Users can log data to the SQL Server or MySQL. People can query the data on an aspx page by IE browser.
The demo shows how to program a ASP .NET page to query the SQL Server data.
- Reporter
Can print the trend line or data from the database - High/Low alarm with audio warning
Each AI channel can have its own high/low limitation. Once the AI value over high limitation or below low limitation, the alarm light will be triggered with audio. The alarm status will keep warning till users switch off the alarm light. - Can search for DCON modules and M7000 serial modules
For DCON modules,7000, 87K, 8000 modules can be searched.
For Modbus RTU modules,M7000 serial modules can be searched and automatic setting the gain and offset. - Value scaling
Set gain and offset can scal analog values from volt or amp unit to another physical measurement unit.
Include calculating function( given 2 points to calculate the gain and offset).
For example: rpm for rotation, kg for weight.
- Support 3 level account
- Programming skill needless
- All operation are done by click mouse and enter value.
Specifications
Communication | |
Protocols | DCON, Modbus RTU, Modbus ASCII, and Modbus TCP |
Control & Logic | |
Virtual Channel Definition | The user can easily consolodate data into a virtual channel by tagging channel names. For example: VC3 = (AI_2 + AI_3) / 2 |
Control Logic (VB Script) | The user can edit the script to set the output values or to calculate data into virtual channels. You can set the channel values by channel tag names. For example: If AI_2 > 50 then DO_3=1 |
Alarm Notifier (by sending SMS or E-mail) | The user can link a cell phone number and email address with the data logger values. When the channel value is over the alarm value, or when the value goes back to normal, the messenger will send an SMS message (using GSM Modem with PDU mode supported) or by E-mail (using ethernet). |
Value Conversion | Set gain and offset can convert analog values from volt or amp unit to another physical measurement unit. This includes using a calculating function(using 2 points to calculate the gain and offset). For example: rpm for rotation, kg for weight. |
Configuration | |
No Programming Needed! | All operations are done by the click of a mouse and entering values. |
Flexible module configuration | Each module and I/O point can be set to a different description and color. |
Flexible workgroup configuration | Each channel can be assigned to a workgroup for easier organization. |
Module Search | The user can search for DCON and M7000 serial modules - For DCON modules,7000, 87K, 8000 modules can be searched. For Modbus RTU modules,M7000 serial modules can be searched and can automatically set the gain and offset. |
High/Low alarm with audio warning | Each AI channel can have its own high/low limit. Once the AI value over high limit or below low limit, the alarm light will be triggered with audio. The alarm status will keep warning until the user switches off the alarm light. |
Views | |
Real time data trend (with zoom in and zoom out) | Each trend line can store more than 86400 records. Using this, you can visualize your data on a graph. |
Layout view | The user can set a background picture and drag-and-drop I/O points to mapping locations. User can also change the visual channel layout object as Linear Gauge, Angular Gauge, Toggle, Number LED... |
IP Camera Viewer | The user can add an IP camera's web address, and then add it to group. Then the layout display will show the web page in a sub window. |
Access database & SQL supported | The database can be exported to an Excel file or CVS file. |
Print Reports | The user can print reports from the trend line or data from the database. |
Supports 3 Permission Levels
Admin
|
Power
|
User
|
|
Modify the project |
●
|
○
|
○
|
Account management |
●
|
○
|
○
|
Start/Stop projects |
●
|
●
|
○
|
Set AO/DO values |
●
|
●
|
○
|
Switching group pages |
●
|
●
|
●
|
● allowed ○ not allowed
Features
|
Basic Edition
|
Advanced Edition
|
Time Limit
|
No
|
No
|
Number of Virtual Channels
|
32
|
256
|
Control Logic
|
Enabled
|
Enabled
|
Number of Web Cameras
|
1
|
10
|
Alarm contacts to (email or SMS)
|
2
|
10
|
IO Tag Number
|
64
|
1024
|
License key
|
Free with Registration |
Registration with product serial number, PC ID Code, and personal information
to get a license key.
Each product serial number can request 3 license keys for 3 PC. Get License Key |
Price | FREE | $729.00 |
Supported Modules (You need one ICP DAS Module in your network to use EZ Data Logger):
- DCON modules (I-7000, I-87K, I-8000 series)
I-7000 Remote I/O Module
I-8000 Main Control Unit
RU-87P1/2/4/8 RS-485 Intelligent I/O expansion unit
I-87K1/4/5/8/9 RS-485 I/O expansion unit
USB-87P1/2/4/8 Intelligent USB I/O expansion unit
8K and 87K I/O Modules
PDS-700 Series DI/DO Model
ZigBee I/O Module
- Modbus/TCP
I-8000E- MTCP
I-8000E-MTCP Support modules
ET-6000
ET-7000
ET-7200
ISaGRAFcontrollers ( I-8417/8817/8437/8837, I- 7188EG, I-7188XG, Wincon-8x37 )
I-7188E-MTCP
I-7188EF-016 Ethernet to FRnet Convert
- Modbus/RTU
M-7000 series
tM series
- M2M RTU
G-4500 / GT-540
M-7000 serial modules
- USB I/O
USB-2000 module
- Devices with Modbus RTU, Modbus Ascii, Modbus TCP protocols
Limitation:
- Most 32 channels for each work group
- One ICPDAS Modbus device to active all modbus drivers (see.Q2 )
- Supported OS :Windows 98/NT/2000/XP/Vista/Windows 7