Free Expert Technical Support secure online transactions
Translate - French Fr  |  Spanish Sp 
    Cage/NCAGE Code: 3FNF0
Cage/NCAGEISO 9001 and ISO 9002 company

Free Shipping

Guarantee

    

WISE-7902

> Programmable Automation Controllers > WISE Expansion I/O Modules > WISE-7902
envelopeE-mail this Product
Product Reference & Support
  • User's Manual
  • Cut Sheet
  • Firmware
  • MiniOS7 Utility
  • DCON Utility
  • WISE Firmware Uploader

  • FRnet Remote I/O PoE Module
    WISE-7902: $459.00  add to cart
    Please Call 1-888-971-9888 for Volume discount pricing!
    Features

    WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.

    WISE-7902 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7902 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc.

    This module WISE-7902 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It supports an I/O expansion bus to implement various I/O functions such as D/I and D/O according to the using FRnet modules: FR-2053T, FR-2054T, and FR-2057T.

    Features

    • Built-in Web Server for IF-THEN-ELSE rule setting
    • Built-in IF-THEN-ELSE rule enigne for logic operation
    • No more programming. Just click and get done!
    • Support IO, Counter, Timer, Email operations
    • Modbus/TCP Protocol for SCADA Software Seamless Integration
    • IEEE 802.3af-compliant Power over Ethernet (PoE)
    • 10/100 Base-TX Ethernet
    • I/O expansion bus
    • Support FRnet Modules: FR-2053T, FR-2054T, FR-2057T

    Applications

    Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc.

    Specifications & Additional Information
    CPU Module
    CPU 16-bit CPU
    SRAM 512 KB
    Flash 512 KB
    EEPROM 16 KB
    NVRAM 31 Bytes
    OS MiniOS7
    RTC (Real Time Clock) RTC Provide seconds, minutes, hours, date of week/month; month and year, valid from 1980 to 2079
    64-bit Hardware Serial Number Yes
    Watchdog Timers Yes (0.8 second)
    Communication Ports
    Ethernet RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators)
    COM 1 No (Unsupported by WISE firmware)
    COM 2 No (Unsupported by WISE firmware)
    FRnet Max. 1 M
    LED Indicators
    System LED Yes (Red) 
    LED Display -
    Special Indicator PoE LED (Green)
    Mechanical
    Dimensions (W x H x D) 72 mm x 123 mm x 35 mm
    Installation DIN-Rail or Wall Mounting
    Environment
    Operating Temperature -25 ~ +75 °C
    Storage Temperature -40 ~ +80 °C
    Ambient Relative Humidity 5 ~ 90% RH, non-condensing
    Power
    Protection Power reverse polarity protection
    Frame Ground Yes (for ESD Protection)
    Input Range +12 ~ +48 VDC
    Power over Ethernet (PoE) IEEE 802.3af Class 1
    Power Consumption 1.5 W

    Software Specifications

    Functions
    Rule Configuration Website Access Web server on WISE controllers to edit and upload logic rules through web browser.
    36 IF-THEN-ELSE Logic Rules 3 IF conditions with AND or OR operators
    3 THEN actions and 3 ELSE actions
    48 Internal Registers Hold temporary variables and read/write data via Modbus/TCP address.
    12 Timers Delay / Timing functions.
    12 Schedules Setup prescheduled routine tasks.
    12 Emails Send Email messages to pre-set Email receivers.
    12 CGI Commands Send pre-set CGI commands.
    12 Recipes Set up THEN/ELSE action groups.
    8 P2P remote modules Set up the connection information for the remote WISE modules.
    Modbus/TCP Protocol Real time control and monitoring I/O channels and system status of controllers via SCADA software.
    IF Conditions
    DI Channel ON、OFF、ON to OFF、OFF to ON、Change
    Internal Register =、>、<、>=、<=(value)
    DI Counter =、>、<、>=、<=(value)、Change
    DO Counter
    Timer Timeout、Not Timeout
    Schedule In Range、Out of Range
    P2P DI、AI、DI counter、DO counter、IR
    Rule Status Enable、Disable
    THEN / ELSE Actions
    DO Channel ON、OFF、Pulse Output
    Internal Register Change the value
    DI Counter Reset
    DO Counter
    Timer Start、Stop
    Schedule
    Email Send
    CGI Commands
    Recipe Execute
    P2P DO(On/Off)、AO、IR
    Rule Status Enable、Disable
    Related Products
    FR-2054T
    8-channel FRNet Isolated Digital Input and 8-channel Isolated Digital Output Module

    More Info
    KingView
    High-Performance PC Software for Building Data Information Service Platform or SCADA System

    More Info
    NS-205PSE
    Unmanaged 5 Port 10/100 Base-T(x) Power Over Ethernet Switch (PSE). Compatible with Sixnet, Stride, Hirschmann, and other industrial Ethernet Switches.

    More Info
    DIN-KA52F-48
    48V/0.52A, 25 W Power Supply with Din-Rail Mounting

    More Info
    I-950-ENC IP66
    Small Industrial Enclosure with dimensions 254mm x 180mm x 90mm

    More Info
    FR-2053TA
    16-Channel FRNet Isolated Sink/Source Digital Input Module

    More Info
    WISE-7160
    6-channel Power Relay Output and 6-channel Isolation Digital Input PoE Module, web browser configurable, allows users to implement IF-Then Else If type control logic and communicable over Modbus TCP

    More Info
    X324
    4-channel D/A (0~5V) add 4-channel D/O (RoHS) Expansion Board

    More Info


    Home  Site Map  Policies  E-Commerce Information  Online Demo  Links  Press  FAQS  Solution Providers  Articles   Employment Opportunities
    ©2012 ICP DAS USA. All rights reserved.