Download Now

Enter your information or login to view the document.


×
User-defined I/O & Data Logger 16-bit Module with SMS Function for Modbus TCP Devices (RS-232, RS-485, Ethernet) 2 W Power consumption.  Has operating temperature range of -25°C ~ +75°C (-13°F ~ +167°F). WISE-5801-MTCP is phased out and replaced by WISE-5231M-4GE.

WISE-5801-MTCP

User-defined I/O & Data Logger 16-bit Module with SMS Function for Modbus TCP Devices (RS-232, RS-485, Ethernet) 2 W Power consumption. Has operating temperature range of -25°C ~ +75°C (-13°F ~ +167°F). WISE-5801-MTCP is phased out and replaced by WISE-5231M-4GE.

    Item Not Available  


Features

The WISE-5801-MTCP has officially been phased out and will no longer be available. It has now been replaced by WISE-5231M-4GE.

WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS USA, Inc. that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the labor and cost spent on system development.

An I/O expansion bus to implement various I/O functions such as D/I, D/O, A/D and D/A according to the XW-Board is supported by the WISE-5801-MTCP. In addition, WISE-5801-MTCP also supports Modbus TCP slave devices. Based on the connection ability with Modbus TCP slave devices, WISE-5801-MTCP can provide user more flexibility in application field.

WISE-5801-MTCP supports Modbus TCP/RTU protocol to make seamless integration with SCADA software available. It includes all advantages which WISE series controllers can provide. In addition, WISE-5801-MTCP provides data logger function with microSD card, it can record I/O channel value by event trigger or regular time period. The data files can be sent back by Email or FTP. WISE-5801-MTCP also features SMS sending function for alarm report and SMS command receiving function. All setting can be completed through browser.

  • Built-in Web Server for IF-THEN-ELSE
  • Built-in IF-THEN-ELSE rule engine for logic operation
  • Support I/O, Counter, Time, Schedule, Email, Recipe operation
  • No more programming. Just click and get done!
  • Data logger and data files send back function supported
  • Modbus TCP/RTU Protocol for SCADA Software Seamless Integration
  • Support XW-Board
  • Support Modbus TCP Slave Devices (Up to 7)
  • SNTP Time Synchronization Supported
  • Support SMS (GSM: Quad-band 850/900/1800/1900 MHz)

Specifications

System
CPU
16-bit CPU
SRAM
768 KB
Flash
512 KB
MicroSD Expansion
Support 1/2/4 GB microSD
RTC (Real Time Clock) Provide second, minute, hour, date of week, month and year
Watchdog
Yes
Communication Ports
Ethernet RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X)
COM 1
RS-232 (TxD, RxD, RTS, CTS, GND), non-isolated, Speed: 115200 bps max.
COM 2
RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed : 115200 bps max. (Reserved)
LED Indicators
System LED
Yes (Red)
Ethernet Link LED
Yes (Green : Ethernet link detected, Flashing Green : Ethernet packet received)
Hardware Expansion
I/O Expansion Bus
Yes
SMS Function
Frequency Band
Quad-band 850/900/1800/1900 MHz
Mode
Text and Unicode mode
Power Requirements
Protection Power Reverse Polarity Protection
Frame Ground Yes (for ESD Protection)
Input Range 12 ~ 48 VDC
Redundant Power Input Yes
Power Consumption 2.0 W; Data Link: 150 ~ 400 mA (peak) @ 24 VDC
Mechanical
Dimensions (W x H x D)
91 mm x 132 mm x 52 mm
Installation
DIN-Rail
Environment
Operating Temperature
-25°C ~ +75° (-13°F ~ +167°)
Storage Temperature
-30°C ~ +80°C (-22°F ~ +176°F)
Ambient Relative Humidity
10 ~ 90% RH (non-condensing)

Software Specification

Functions
Rule Configuration Website
Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules
3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions
48 Internal Registers
Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers
Delay / Timing functions.
12 Schedules Setup prescheduled routine tasks.
12 Emails Send Email messages to pre-set Email receivers.
12 SMS Send SMS to pre-set mobile phone numbers.
12 CGI Commands Send pre-set CGI commands.
12 Recipes Set up THEN/ELSE action groups
Data Logger Set up the Data Logger configuration, include the data record format, and data file sending operation.
Modbus TCP/RTU Protocol
Real time control and monitoring I/O channels and system status of controllers via SCADA software.
IF Conditions
DI Channel ON、OFF、ON to OFF、OFF to ON、Change
AI Channel =、>、<、>=、<=(value)
=、>、<、>=、<=(value)、Change
Internal Register
DI Counter =、>、<、>=、<=(value)、Change
Timer Timeout、Not Timeout
Schedule
In Range、Out of Range
Rule Status
Enable、Disable
THEN / Else Actions
DO Channel ON、OFF、Pulse Output (apply to XW-Board only)
AO Channel Change the value
Internal Register
DI Counter Reset
Timer Start、Reset
Schedule Enable、Disable
Email Send
SMS
CGI Commands
Recipe Execute
Data Logger Start、Stop、One-Time Log
Rule Status
Enable、Disable

References and Support

Customer Reviews (0)

Be the first to leave a review.

Recently Viewed Items

×

Write a Review

Name


E-mail


Phone


Rating: out of 5 Stars
Review (max 1000 characters)

characters left