Product Reference & Support :
  • Quickstart Guide
  • User's Manual
  • Hardware
  • Wiring
  • Software


  • DeviceNet Master / Modbus TCP Server Gateway
    Product Pricing:
    I-7243D: $529.00  add to cart
    Volume Customers, Please Call 1-888-971-9888 for discount pricing!
    Features
    The I-7243D from ICP DAS is a solution that provides a communication protocol transfers the DeviceNet and Modbus/TCP protocol and solves a mission-critical problem: connecting an existing DeviceNet network to Ethernet-base PLCs and PC-based configuration and monitor system. it enables DeviceNet networks to be coupled together over the Internet/Ethernet, whereby remote monitoring and control is possible.

    The I-7243D can be a DeviceNet master device in the CAN bus on the DeviceNet network. It is a “Predefined Master connection Set”, and supports Group 2 only Server functions to communication with slave devices. In addition, we also provide Utility software for users to configure their device parameters for the I-7243D. The following figure shows the application architecture for the I-7243D.

    • Programmable DeviceNet Master MAC ID.
    • Programmable DeviceNet transfer-rate 125K, 250K, 500K.
    • Supports maximum DeviceNet devices up to 63
    • Predefined Master/Slave Connection Set
    • The maximum Fragment number is (Input/Output) up to 64
    • Supports I/O Operation Mode: Poll, Bit-Strobe and Change Of State/Cyclic
    • Supports one Poll, one Bit-Strobe, one COS, one Cyclic IO connection for each DeviceNet device when connected with this module.
    • Supports on-line adding device into and removing device from network.
    • Supports boot-up auto communicate with slave devices.
    • Converter single Mobbus/TCP to multi Modbus/RTU, setting by Utility
    • Supports VxComm technique for every COM port of controller, set by Utility
    • Allowed multi-client (or master) access simultaneously

    Modbus RTU, DeviceNet, VxComm Technique
    • Applications:

      • Control Systems
      • Building Automation
      • Factory Automation
      • Districuted Data Acquisition
    • Data Interchange between Modbus TCP and DeviceNet
      • I-7243D provides centralized data storage (Internal Memory) for data that is shared between the DeviceNet and Modbus/TCP network.
      • Data is placed into the "nternal Memory” by one network interface
      • Allowing the data to be read/wrote through the other network interface.
    Internal Memory Table
    • I-7243D Utility
      • Add/Remove online DeviceNet devices via Ethernet
      • Monitor and configure devices online via Ethernet.
      • Get/Set Modbus/TCP input/output memory address
      • Supports DeviceNet I/O mapping table.
      • Shows DeviceNet devices connection statuses.
      • Supports communication mode setting.

    I-7243D Utility

     

    • Typical Applications
      • Modbus/TCP server to DeviceNet master gateway
        • The I-7243D can act as a Modbus/TCP server to DeviceNet master gateway. Using the module, users don’t need to take care of the detail of the DeviceNet protocol. The module will implement the DeviceNet protocol automatically. It mainly supports the Predefined Master/Slave Connection Set functions to allow users to merge I/O data into DeviceNet network by using Modbus/TCP commands.


      • A single Modbus/TCP to multi-Modbus/RTU converter
        • I-7243D can be a single Modbus/TCP to multi-Modbus/RTU converter. You can simply use the Utility software to configure the device and then set connections between SCADA HMI software and the I-7243D.

    Modbus/TCP to multi-Modbus/RTU converter

      • Protocol Converter with VxComm technique
        • I-7243D can also be able to link to serial devices that do not support Modbus/RTU.
        • To use this function, you will need to install VxComm driver on host PCs.
        • After installation, you will be able to access the remote COM ports via the standard serial driver.

    Protocol Converter with VxComm technique

    Specifications & Additional Information

    Model

    I-7243D

    CPU

    80186-80 M Hz CPU, or compatible

    Flash

    512K bytes

    SRAM

    512K bytes

    EERROM

    16K bytes

    Ethernet port

    10/100 Base-T

    Real Time Clock

    Year-2000 compliance; seconds, minutes, hours, date of the month, year, valid up from 1980 to 2079

    CAN Signal Support

    CAN_H, CAN_L

    Connecter

    5-pin screw terminal connecter

    Power Consumption

    3W

    COM1

    RS-232: TXD, RXD, RTS, CTS, GND

    COM2

    RS-485: D2+, D2-

    COM Speed

    115200 bps max

    CAN Controller

    Phillip SJA1000T CAN Controller

    CAN Transceiver

    Phillip 82C250 CAN Transceiver

    LED Directors

    MS, NS, RUN

    Display

    7-segment LED: 5 digits

    Isolated

    1K VDC isolation on the CAN side

    Reauired Supply Voltage

    +10~+30VDC

    Operating Temp

    -25°C to 75°C

    Storage Temp

    -40°C to 85°C

    Himidity

    5~95%

    Dimensions

    123mm x 64.5mm x 19.6mm

    Related Products
    I-950-ENC IP66
    Small Industrial Enclosure

    More Info
    DIN-KA52F
    24V/1A Power Supply (Din-Rail Mount)

    More Info
    DP-640
    24V/1.7A Power Supply

    More Info
    PWR-24/110
    24V/0.1 AMP Power Supply

    More Info
    I-3625-ENC
    Large IP66 Industrial Enclosure

    More Info

    Home  Site Map  News  Policies  E-Commerce Information  Online Demo  Links  Press  FAQS  Solution Providers
    © 2005 ICP DAS USA. All rights reserved.