| ET-6052D |
|
| Product Reference & Support : |
|
| Web Based I/O Module with 8 Digital Output and 14 Digital Input Channels |
ET-6052D: $479.00
|
|
|
|
|
The ET-6000 series also supports various Modbus functions. For example, Modbus/TCP slave, Modbus/TCP to Modbus/RTU gateway, Modbus/RTU master, Modbus/RTU slave; meaning the ET-6000 series can easily be integrated into any SCADA software environment using the Modbus protocol.
The ET-6000 series modules are designed to be used in Industrial monitoring and measurement applications. The hardware has been manufactured to survive in harsh and noisy environments. The module contains 3-way isolation against noise and surge signals, has a wide range of power input (+10 ~ +30VDC) and can operating at temperature ranging from -25°C ~ +75°C. |
| Specifications & Additional Information |
|
|
- Built in Web Server
- Each ET-6000 module has a built - in web server that allows the users to easily configure, monitor and control the module from a remote location using a regular web browser.
- Web HMI
- The Web HMI function allows users to create attractive, dynamic web pages to monitor and control the I/O points. Users can upload specific I/O layout pictures (bmp, jpg, gif formats) and define a description for each I/O point. No HTML or Java skills are needed to create the web pages.
- Communication Security
- An Account and password is needed when logging into the ET-6000 web server.
- An IP address filter is included; which can be used to allow or deny connections from specific IP addresses.
- Modbus protocol
- The Modbus/TCP slave function on the Ethernet port can be used to provide data to remote SCADA software.
- The Modbus/RTU slave function on the RS-232 port can be used to connect to a local HMI.
- The Modbus /TCP to Modbus/RTU gateway function through the Ethernet port to the RS-232 port can be used to upgrade a serial device with Ethernet communication ability
- Built-in Multi-function I/O
- An LED indicator is used for each DI or DO channel
- All Digital Output modules provide :
- Power on value (On boot up, the DO status is set to the Power-on value)
- Safe value (If Modbus/TCP communication is lost for a specified period,the DO status is set to the safe value)
- All Digital Input modules provide :
- High/Low latched status
- DI channels can also be used as DI status and 16-bit low speed (100Hz) counters
- All-in-one module
- The various I/O components are mixed with multiple channels in a single module
- Provides the most cost effective I/O usage and enhances performance of the I/O operations
- 3-way isolated noise/surge protection
- Potect the hardware from damage caused by noise and surges
- Designed with isolation circuits for Ethernet, I/O and Power.
- Portable Configuration
- All configuration settings can be saved to the EEPROM on the ET6000
- EEPROM is mounted on a daughter board (called the “portable” board)
- The settings can stored and easily backed up and moved.
- Built-in Dual Watchdog
- Dual Watchdog consists of a Module Watchdog and a Host Watchdog.
- Module Watchdog is a built-in hardware circuit
- Can be used to monitor the operation of the module
- Will reset the CPU module if a failure occurs in either the hardware or the software.
- Host Watchdog is a software function
- Can be used to monitor the operating status of the host
- Is used to prevent network communication problems or host failures
- Automatic MDI / MDI-X crossover for plug-and-play
- RJ-45 port supports automatic MDI/MDI-x that can automatically detect the type of connection to the Ethernet device without requiring special straight or crossover cables.
- Ventilated housing designed to operate between -25°C and +75°C
- The ET-6000 is housed in a plastic-based shell/case with a column-like ventilator that helps to cool the working environment inside the shell/case
- Allows the ET-6000 to operate at temperatures ranging from -25°C and +75°C.
- I/O pair connection
- This function is used to create a DI to DO pair through the Ethernet.
- Once the configuration is complete, the ET-6000 module can poll the status of local DI channels and then use the Modbus/TCP protocol to continuously write to a remote DO device in the background.

ET-6052D |
| CPU |
80186 , 80MHz |
| SRAM |
512 KB |
| Flash Memory |
512 KB |
| EEPROM |
16 KB |
| Dual Watchdog |
Yes |
| Serial Port |
RS-232 (TXD, RXD, GND) (115200 bps Max.) |
| Ethernet Port |
10 / 100 Base TX (With Link, Activity LED Indicator) |
| 7 Segment LED Display |
5 Digits |
| System LED Indicator |
4 |
| Push Button |
4 |
Output Channels |
8 (Source) |
| LED Indicator |
Yes |
| Output Type |
Isolated (N-MOSFET, Open Source) |
Max Load Current |
1.4A/ channel |
Load Operating Voltage |
10Vdc to 40Vdc |
External Power Voltage Range |
12Vdc to 45Vdc |
| Over-Voltage Protection |
+48 VDC |
| Direct Drive Power Relay Module |
Yes |
| Short Circuit Protection and Current Limitation |
Yes |
| Switching Inductive Loads |
Yes |
| Intra-module Isolation, Field to Logic |
3750V rms |
| Input Channels |
14 (Sink/Source) |
| LED Indicator |
Yes |
| Input Type |
Isolation, One Common/Ground for All Digital Inputs |
| Input Impedance |
10K Ohms, 0.5W (For Wet Contact) |
| Dry Contact (Source) |
On Voltage Level : Close to GND |
| Off Voltage Level : Open |
| Wet Contact (Sink/Source) |
On Voltage Level : +10 to 50Vdc |
| Off Voltage Level : +3V (Max.) |
| Each Channel Can Be To Dry Contact or Wet Contact |
Yes |
| Counters |
Channels : 14 |
| Max. Input Frequency : 100Hz |
| Min. Pulse Width : 5ms |
| Intra-module Isolation, Field to Logic |
3750V rms |
| 3 Way Isolation - Ethernet |
1500V rms |
| 3 Way Isolation - I/O |
3750V rms |
| 3 Way Isolation - Power |
1000 VDC |
| Din Rail Mount |
Yes |
| Wall Mount |
Yes |
| Power Input |
+10 to +30 VDC |
| Power Consumption |
3.0W |
| Operating Temperature |
–25°C ~ +75°C |
| Storage Temperature |
: –30°C ~ +75°C |
| Relative Humidity |
10% to 95% Non-condensing |
| Certifications |
CE, FCC |
| Dimensions |
90mm x 111mm x 70mm (W x D x H) |
|
|
|
|
|

|